6.1






























EN-14
System-specific parameters
The return set temperature hysteresis forms
the neutral zone for operation of the heat pump.
If the temperature "Return set temperature plus
hysteresis" is reached, the heat pump switches
itself off. If the temperature "Return set
temperature minus hysteresis" is reached, the
heat pump switches itself on.
settings to lower the heating characteristic
curve of heating circuit 1
Sets the times during which the temperature in
heating circuit 1 is to be lowered.
Sets the temperature value by which the
heating characteristic curve of heating circuit 1
is to be lowered when the temperature is
lowered
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is
lowered. Operations to lower the temperature
that exceed a weekday are activated or
deactivated at the end of each day accordingly.
Settings to raise the heating characteristic
curve of heating circuit 1
Sets the time during which the temperature in
heating circuit 1 is to be raised.
Sets the temperature value by which the
heating characteristic curve of heating circuit 1
is to be raised when the temperature is raised.
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is raised.
Operations to raise the temperature that
exceed a weekday are activated or deactivated
at the end of each day accordingly.
Sets the desired return flow set temperature
when dynamic cooling is selected
Sets the room set temperature for silent
cooling.
The actual value is measured by room climate
control station 1
Raises the minimum permissible flow
temperature calculated from the measured
values from room climate control station 1. A
raised value reduces the risk of condensate
forming.
Menu navigation for heating circuits 2 and 3 is
identical
The following heating regulation options are
available for heating circuit 2/3:
* Return flow temperature regulation based on
the external temperature and the set heating
curve
* Return flow temperature regulation via a fixed
setpoint (horizontal heating characteristic
curve)
Setting range
Display
0.5K
Heating circuit 1
... 2 K ...
5K
Heating circuit 1
00:00
Heating circuit 1
...
23:59
0K
Heating circuit 1
...
19K
N
Heating circuit 1
T1
T2
Y
Heating circuit 1
00:00
Heating circuit 1
...
23:59
0K
Heating circuit 1
...
19K
N
Heating circuit 1
T1
T2
Y
10 °C
Cooling function
... 15 °C ...
Heating circuit 1
30 °C
15.0 °C
Cooling function
... 20.0 °C ...
Heating circuit 1
30.0 °C
1,5K
Cooling function
...3,5K...
Heating circuit 1
5K
Heating circuit 2
and 3
External
Heating circuit 2
temperature
and 3
Fixed setpoint
Heating