Configuring the Heat Pump Heating System






























System-specific parameters
Sets the desired domestic hot water
temperature which is to be reached in parallel
operation.
Sets whether the existing flange heater is also
to be used for reheating. If set to "No", domestic
hot water is only heated up to the current HP
maximum temperature (depending on the heat
source temperature).
Sets the time programs for hot water blocks
Sets the times in which domestic hot water
preparation is blocked.
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active for a block. Blocks that exceed
a weekday are activated or deactivated at the
end of each day accordingly.
To carry out a thermal disinfection, the
domestic hot water is heated up once to the
desired temperature. The heating period is
terminated automatically when the set
temperature is reached, at 12:00 p.m. or after 4
hours at the latest.
Sets the start time for the thermal disinfection
Sets the desired hot water temperature which is
to be reached during thermal disinfection
For each day of the week, it is possible to select
whether thermal disinfection is desired at the
set start time.
The circulation pump is started using a paddle
flow switch, for example. When the paddle flow
switch returns to the original position, the
circulation pump operates for the duration of
the set time.
The circulation pump is controlled by a timer
function.
Sets the times at which the circulation pump is
to be activated.
For each day of the week, it is possible to select
whether the circulation pump is activated at the
set start time.
By setting Reset to "Yes", the maximum
calculated domestic hot water temperatures in
HP operation are reset to a value of 65 °C. The
setting is automatically reset to "No".
Setting range
Display
30 °C
Additional HE
... 60 °C ...
Hot water
85 °C
Sensor
No
Domestic hot water
Yes
Flange heater
Domestic hot water
00:00
Domestic hot water
...
23:59
N
Domestic hot water
T1
T2
Y
Hot water
Sensor
Bivalent or flange
heater
00:00
Hot water
...
Sensor
23:59
Bivalent or flange
heater
60 °C
Hot water
... 65 °C ...
Sensor
85 °C
Bivalent or flange
heater
N
Hot water
Y
Sensor
Bivalent or flange
heater
1 min
Circulation
... 5 ...
Pulse
15 min
Circulation
Time
00:00
Circulation
23:59
Time
N
Circulation
Y
Time
No
Hot water
Yes
Sensor
6.1