Download Print this page

Electrolux BLAST CHILLER LW Service Manual page 68

Advertisement

ERROR CODE E3:
This condition causes the following event:
The Alarm Service Led is blinking
The buzzer is active
The display shows the ERROR code
THIS ALARM DOSEN'T STOP THE WORKING CYCLE (CHILLING OR
FREEZING) BECAUSE THE CHECK CONTROL TEMPERATURE WILL BE
DONE BY EVAPORATOR PROBE BUT IT IS NECESSARY TO CALL THE
SERVICE to changed the probe.
This type of error causes the following possible events:
(if present)
turned off (if present), according to the parameter
reference parameter list)
The door heating element is always active
During maintenance the temperature control turn to the evaporator
probe, according to positive or negative evaporator set point (PScF
or nScF).
STORAGE SENSOR FAILURE
ALARMS CONDITIONS
The sterilize process is stopped and the germicidal light
SWICTH OFF ALARMS :
ONLY REPLACEMENT THE PROBE
"E3"
- 68 -
OdS
(see

Hide quick links:

Advertisement