Micro switch Door Device
It's a magnetic switch that in case of
door open the led start/stop button will
be flashing ,the cell motor ventilator will
be off and if keep more then 30 second
also the compressor will be off ; more of
5 minutes whit door open will appear in
the display the alarm b4 (door open
cycle active only). The magnetic, to
close the circuit of micro switch, is
positioned inside the door (foamed) and
it's not possible replace .
The magnetic switch is positioned inside
of control panel and it is fixing with
screws.