TCX1000 Programmable ROADM Quick Start Guide

Connecting AC Power to the TCX1000-RDM20

8
To connect AC power to a TCX1000-RDM20:
Prevent ESD damage to your equipment by attaching an ESD grounding strap to your
1.
bare wrist, and then connecting the strap to an approved site ESD grounding point.
Ensure that the power supplies are fully inserted in the chassis and the latches are
2.
secure.
Insert the coupler end of the power cord into the AC power cord inlet on the AC power
3.
supply faceplate for each power supply.
If the AC power source outlet has a power switch, set it to the off (
4.
NOTE:
The TCX1000-RDM20 powers on as soon as power is provided to
the power supply.
Insert the power cord plug into an AC power source outlet for each power supply. See
5.
Figure 6 on page
8.
Figure 6: Connecting an AC Power Cord to an AC Power Supply in a TCX1000-RDM20
If the AC power source outlet has a power switch, set it to the on (
6.
Verify that the LEDs on each power supply are lit green. If any are lit yellow, remove
7.
power from the power supply, and replace the power supply (see Installing a Power
Supply in a TCX1000-RDM20 in the TCX1000 Programmable ROADM Hardware Guide).
Do not remove the power supply until you have a replacement power supply ready;
power supplies must be installed in the TCX1000-RDM20 to ensure proper airflow.
CAUTION:
Replace a failed power supply with a new power supply within
five minutes of removal to prevent chassis overheating.