TCX1000 Programmable ROADM Quick Start Guide

Step 10: Enabling OSC Forwarding on the TCX1000-RDM20

Table 1: OSC Forwarding Conditions
Enable OSC Forwarding If
The TCX1000-RDM20 line port is connected to a TCX1000-ILA.
The TCX1000-RDM20 line port is connected to a TCX1000-RDM20
without DCN access.
18
NOTE:
If you want to enable OSC forwarding, you can follow the steps in
the Enabling OSC Forwarding on the TCX1000-RDM20 and then apply the
restart warm
The session closes and the TCX1000-RDM20 reboots. The TCX1000-RDM20 now
has a static IP address.
Use the proNX Optical Director to provision, monitor, and activate services on a
8.
TCX1000-RDM20 optical network. See the proNX Optical Director Installation Guide
at
https://www.juniper.net/documentation/
Optical Director software on supported servers.
NOTE:
The proNX Optical Director uses the CLI username and password
to log in via NETCONF.
The TCX1000-RDM20 is capable of providing connectivity to a remote site through the
Optical supervisory channel (OSC). OSC forwarding must be enabled when the
TCX1000-RDM20 is connected to a remote site without DCN access or is connected to
a TCX1000-ILA. See the TCX Series Optical Transport System Feature Guide at
www.juniper.net/documentation/en_US/release-independent/tcx/information-products/
pathway-pages/tcx1000-index.html
rules and restrictions, and configuration examples.
After you have completed assigning the IP address, you can enable OSC. OSC forwarding
is disabled by default.
See
Table 1 on page 18
for when you must enable or disable OSC on the TCX1000-RDM20:
To enable OSC forwarding on the TCX1000-RDM20 from the CLI:
Enter the user ID:superuser.
1.
Enter the password: <password>.
2.
command.
for instructions on how to install the proNX
for detailed information on network requirements,
Do not enable OSC Forwarding If
The TCX1000-RDM20 line port is connected to a
TCX1000-RDM20 that is on a different IP subnet.