Sequence
1. HMI boots on the NCU with bus address 13, if the NETNAMES.INI has not been not
2. NCU bus address has been changed, this alarm apppears:
3. Point no. 6. As for HMI Embedded
Power up with HMI Advanced option
If the control unit switchover option is installed, a configuring problem can be corrected as
follows:
1. Select the channel menu with the input key
2. Go to the area switchover screen by pressing Recall
3. Select commissioning.
Required documentation
References:
/BH/ Operator Components Manual
/IAD/ Commissioning Manual
/FB1/ Function Manual, Basic Functions; P3, Basic PLC Program
The following are described here:
● MPI/OPI bus structure, bus addresses, /IAD/
● Bus terminator, /IAD/, /FB/S7
● Connection of MCPs via basic PLC program, /FB/, P3
● DIP FIX settings of MCP, /IAD/
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
2.2 Several operator panel fronts and NCUs with control unit management option
changed (original factory settings).
"120201 name: communication failed"
– Set the connection to 1:1 in the Commissioning/HMI/Operator panel operating area
and enter "13" as the NC address
– Confirm with OK and boot the HMI
Note
In the event of an error, check the active bus nodes in the menu:
• Commissioning/NC/NCK addresses (HMI Embedded, HT6 and HMI Advanced)
• Commissioning/HMI/Operator panel (HMI Advanced)
Note
After performing series machine commissioning, a Power On must be performed on the
PCU so that the bus nodes (PLC, NC, PCU) can resynchronize.