SATO SG112 ex Programming Reference Manual page 390

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[Coding Example]
<A>
<IZ>1,5,12345,DATA --------- (1)
<IZ>2,4,0001,QTY ---------- (2)
<Z>
 
(1)
DATA
(2)
12345
ONLINE
QTY
0001
ONLINE
[Supplementary Explanation]
-
The stored data is cleared when this product is powered off.
-
The input data is displayed up to 16 digits. When the data exceeded 16 digits, display the data
with [←] [→] key scrolling.
-
The printer returns back to the original display after input.
-
Data input and message display is only available in the online state. Data input is not available
when offline state and error state.
-
The message is left aligned. When the message is less than the maximum display digit (16
digits), space (20H) is filled.
-
The moving range by [←] [→] keys for input cursor depends on the input digit specification.
-
Invalid code in the displayed data will be replaced with space (20H) and displayed.
-
The code can be changed by [↑] [↓] keys is 20H to 7EH in ASCII.
-
It is not possible to change by key input when control code (00H to 1FH in ASCII) is included in
the default data.
Even the code has been changed by input cursor, the applicable code is discarded when storing
to the internal buffer.
-
The command error occurs when input digit and the number of default data is not consistent.
-
The error will not be occurred even a printer error is detected during input waiting.
-
This command is invalid when the keys are used exclusively by <I#>1.
ENTER
QTY:000000
ENTER
QTY:000000
Internal buffer
No.
Item name
Number
of digits
01
DATA
5
02
QTY
4
03
0
04
0
05
0
06
0
07
0
08
0
09
0
10
0
11
0
12
0
13
0
14
0
15
0
16
0
389
Data contents
12345
0001