[ESC+FW] Ruled / Grid Line Print
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the ruled / grid line.
[Format]
<FW>aabccccc(Peeeeeeee) : Print of ruled line
-
Parameter
a [Line width] = Valid range : 02 to 99 dots
b [Horizontal/vertical direction]
H : Horizontal direction
V : Vertical direction
c [Ruled line length] = Valid range : Refer to [Valid Range] section below.
e [Line pattern] = Valid range : 01 to FFFFFFFF (omissible)
<FW>aabbVcccccHddddd(Peeeeeeee) : Print of grid line
-
Parameter
a [Vertical line width] = Valid range : 02 to 99 dots
b [Horizontal line width] = Valid range : 02 to 99 dots
c [Vertical line length] = Valid range : Refer to [Valid Range] section below.
d [Horizontal line length] = Valid range : Refer to [Valid Range] section below.
e [Line pattern] = Valid range : 01 to FFFFFFFF (omissible)
[Coding Example 1]
Ruled line print, Line width: 4, Horizontal direction, Ruled line length: 400
Grid line print, Vertical line width: 8, Horizontal line width: 8, Vertical line length: 300, Horizontal line
length: 400
<A>
<V>100<H>200<FW>04H400
<V>300<H>200<FW>0808V300H400
<Q>2
<Z>
[Coding Example 2]
Ruled line print, Line width: 4, Horizontal direction, Ruled line length: 400, line pattern: F0F0F0F0
Grid line print, Vertical line width: 8, Horizontal line width: 8, Vertical line length: 300, Horizontal line
length: 400, line pattern: F0F0F0F0
ESC
<FW>
<1B>
<46>
16
None
When the power is OFF
Valid range within items
Valid range between items
Parameter
<57>
Rule   aabccccc(Peeeeeeee)
16
16
Grid   aabbVcccccHddddd(Peeeeeeee)
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
37