Wolf E Series Information Booklet page 39

Electronic control
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

WARMING DRAWER (WWD30)
FIELD SERVICE MODE UNIQUE KEYSTROKES:
KEYPRESS
Enter Diagnostics
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
NOTE: A colon (:) signifies the need to add two zeros (0) to the time shown. (i.e. 1:60 = 16000)
ERROR CODE TROUBLESHOOTING GUIDE:
ERROR CODE
10
(Invalid Checksum Error)
20
(Thermistor Open)
30
(Thermistor Short)
40
(Element Sensing)
50
(Door Switch)
60
(Stuck Relay)
70
(Cable Open)
NOTE: After correcting problem, errors must first be cleared in Field Service Mode before controls will refresh error
display. To clear error codes logged, press and hold "TIMER" up and down arrow keys for 5 seconds, while in Field
Service Mode.
TEMP DISPLAY
rE (Sr if in showroom mode)
Err
Err
Err
Err
Err
Err
Con
(Control On Time) 1:60 = 16000 hr. (See note below)
ELE (Element On Time) 95:00 = 950000 hr. (See note below)
FAn (Fan On Time) 12:60 = 126000 hrs. use (See note below)
Dor (Drawer Open/Close) 1:60 = 16000 cycles (See note below)
119 (Current Temp)
CAUSE
Incorrect checksum
Temperature >300ºF
Temperature <-30ºF
<5º change in temperature over 10
minutes of continuous call for heat.
Occurs only during preheat mode and
the door is closed.
Door switch closed when the keypad is
being operated or unit turned on.
Drawer temperature rises to 250ºF in
any mode/state.
Cable wires that activate element or
fan relays on power board are not
making connection.
PAGE 39
TIMER DISPLAY
0018 (Meaning revision 1.8)
10
20
30
40
50
60
deg
TEST / ACTION
Replace Control Board
In FSM (Field Service Mode), view temper-
ature as view by thermistor. Verify wiring
ok to element. Replace Thermistor if ok.
In FSM (Field Service Mode), view temper-
ature as view by thermistor. Verify wiring
ok to element. Replace Thermistor if ok.
If unit outdoors and temperature below
freezing point, instruct on unit limitations.
Verify Thermal Cutout is not open.
Verify Element is not open.
Replace TCO or Element if open.
Check operation of Door Switch with Ohm
meter. Replace if defective.
Check ambient Temp and installation.
Check TCO. Replace if opened.
Replace Relay Board.
Check connection of comm cable. Use
Figure 5-1 to check voltage and/or ohm
reading of cable. If open, replace.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wwd30Df48Df60

Table of Contents