Time Use Limitation; Fitting Instructions - 3M P95 User Instructions

Particulate respirator
Hide thumbs Also See for P95:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

8576
8. When stored in accordance with temperature and humidity conditions specified below, the product may be used until the "use by" date specified
on the packaging.
Storage Conditions and Shelf Life
Before use, store respirators in the original packaging, away from contaminated areas, dust, sunlight, extreme temperatures, excessive moisture and
damaging chemicals. When stored in accordance with temperature and humidity conditions specified below, the product may be used until the "use
by" date specified on packaging. Always inspect product and conduct a user seal check before use as specified in these User Instructions. If you
cannot achieve a proper seal, do not enter the contaminated area. See your supervisor.
End of Shelf Life
Use respirators before the "use by" date specified on packaging
+86˚F
+30˚C
Storage Temperature Range
-20°C (-4°F) to +30°C (+86°F)
-4˚F
-20˚C
Storage Maximum Relative Humidity
<80% RH
<80%

Time Use Limitation

1. If respirator becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area and dispose of the respirator.
2. If used in environments containing only oil aerosols, dispose of respirator after 40 hours of use or 30 days, whichever is first.
FOR MORE INFORMATION
In United States, contact:
Website: www.3m.com/workersafety
Technical Assistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or 1-651-737-6501
RENSEIGNEMENTS SUPPLÉMENTAIRES
Aux États-Unis :
Internet : www.3m.com/workersafety
Assistance technique : 1 800 243-4630
Autres produits 3M :
1 800 364-3577 ou 1 651 737-6501
Fig. 1

Fitting Instructions

Must be followed each time respirator is worn.
1. Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang freely below your hand (Fig. 1).
2. Position the respirator under your chin with the nosepiece up. Pull the top strap over your head resting it high at the top back of your head. Pull the
bottom strap over your head and position it around the neck below the ears (Fig. 2).
3. Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose area to the shape of your nose by pushing
inward while moving your fingertips down both sides of the nosepiece (Fig. 3).
W Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance. Use two hands.
4. Perform a User Seal Check prior to each wearing. To check fit, place both hands completely over the respirator and inhale sharply (Fig. 4). Be
careful not to disturb the position of the respirator. A negative pressure should be felt inside the respirator. If air leaks around nose, readjust the
nosepiece as described in step 3. If air leaks at the respirator edges, work the straps back along the sides of your head. If you CANNOT achieve a
proper fit, DO NOT enter the contaminated area. See your supervisor.
Fig. 2
2
(English)
Fig. 3
Fig. 4