Download Print this page
3M P100 User Instructions
3M P100 User Instructions

3M P100 User Instructions

Particulate respirator

Advertisement

Quick Links

3
8293
Particulate Respirator P100
User Instructions
IMPORTANT: Keep these instructions for reference.
Respirateur contre les particules P100
Directives d'utilisation
IMPORTANT : Conserver ces directives à titre de référence.
Respirador contra partículas P100
Instrucciones
IMPORTANTE: Conserve estas Instrucciones para referencia futura.
This respirator helps protect against certain particles. Misuse may result in
sickness or death. For proper use, see supervisor, or User Instructions,
or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at
1-800-267-4414.
Ce respirateur protège contre certaines particules. Une mauvaise utilisation
peut provoquer des problèmes de santé ou la mort. Pour tout renseignement
sur l'utilisation adéquate de ce produit, consulter son superviseur, lire les
directives d'utilisation ou communiquer, au Canada, avec le Service technique de
3M au 1 800 267-4414.
Este respirador ayuda a proteger contra ciertas partículas. El mal uso puede
ocasionar enfermedad o incluso la muerte. Para su uso adecuado consulte a
su supervisor, lea las Instrucciones, o llame a 3M en EUA al 1-800-247-3941.
En Canadá llame al Servicio Técnico al 1-800-267-4414. En México llame al
01-800-712-0646. O contacte a 3M en su país.
3M Occupational Health and
Environmental Safety Division
3M Center, Building 0235-02-W-70
St. Paul, MN 55144-1000
Printed in U.S.A.
3M is a trademark of 3M Company.
© 2010 3M Company. All rights reserved.
3M Occupational Health
and Environmental Safety Division
3M Canada Company
P.O. Box 5757 London, Ontario N6A 4T1
Printed in U.S.A.
3M is a trademark of 3M Company, used under license in Canada.
© 2010 3M Company. All rights reserved.
Division des produits d'hygiène
industrielle et de sécurité
environnementale de 3M
Compagnie 3M Canada
C.P. 5757
London (Ontario) N6A 4T1
Imprimé aux É.-U.
3M est une marque de commerce de la Compagnie 3M, utilisées sous licence au Canada.
© 3M, 2010. Tous droits réservés.
3M México S.A. de C.V.
Av. Santa Fe No. 190
Col. Santa Fe, Del. Álvaro Obregón
México D.F. 01210
Impreso en EUA
3M es una marca comercial de 3M Company.
© 2010 3M Company. Todos los derechos reservados.
PAGE 1 OF 6
W WARNING
W MISE EN GARDE
W ADVERTENCIA
IMPORTANT
Before use, wearer must read and understand
these User Instructions. Keep these instructions
for reference.
Use For
Particles such as those from processing minerals,
coal, iron ore, flour, and certain other substances.
Liquid or oil based particles from sprays that do
not also emit vapors. Metal fumes produced from
welding, brazing, cutting and other operations
involving heating of metals. Radioactive
particulate materials such as uranium and
plutonium. For additional information on 3M use
recommendations for this class of respirator
please consult the 3M Respirator Selection Guide
found on the 3M OH&ESD website at
34-8705-2291-8
www.3M.com/OccSafety or call 1-800-243-4630
in U.S.A. In Canada call 1 800 267-4414.
Do Not Use For
Do not use for gases and vapors, asbestos or
sandblasting; particulate concentrations that
exceed either 10 times the occupational exposure
limit or applicable government regulations,
whichever is lower. This respirator does not
supply oxygen.
Biological Particles
This respirator can help reduce inhalation
exposures to certain airborne biological particles
(e.g. mold, Bacillus anthracis, Mycobacterium
tuberculosis, etc.) but cannot eliminate the
risk of contracting infection, illness or disease.
OSHA and other government agencies have
not established safe exposure limits for these
contaminants.
Use Instructions
1. Failure to follow all instructions and limitations
on the use of this respirator and/or failure
to wear this respirator during all times of
exposure can reduce respirator effectiveness
and may result in sickness or death.
2. Before occupational use of this respirator, a
written respiratory protection program must be
implemented meeting all the requirements of
OSHA 29 CFR 1910.134 such as training and
fit testing, medical evaluation, and applicable
OSHA substance specific standards. In Canada,
CSA standard Z94.4 requirements must be
met and/or requirements of the applicable
jurisdiction, as appropriate.
3. The particles which can be dangerous to your
health include those so small you cannot see
them.
4. Leave the contaminated area immediately and
contact supervisor if dizziness, irritation, or
other distress occurs.
5. Store the respirator away from contaminated
areas when not in use.
6. Inspect respirator before each use to ensure
that it is in good operating condition. Examine
all the respirator parts for signs of damage
including straps, buckles, noseclip, foam
faceseal and facepiece material. The respirator
should be disposed of immediately upon
observation of damaged or missing parts.
7. Dispose of used product in accordance with
applicable regulations.
Use Limitations
1. This respirator does not supply oxygen. Do
not use in atmospheres containing less than
19.5% oxygen.
2. Do not use when concen
contaminants are imme
to life and health, are un
concentrations exceed 1
permissible exposure lim
to specific OSHA standa
government regulations
3. Do not alter, abuse or m
4. Do not use with beards
or other conditions that
between the face and th
the respirator.
5. Respirators may help pr
against certain airborne
however, they will not pr
other routes such as the
require additional person
equipment (PPE).
6. This respirator is design
professional use by adu
trained in their use and
respirator is not designe
children.
7. Individuals with a compr
system, such as asthma
should consult a physici
medical evaluation prior
Time Use Limitations
1. If respirator becomes da
or breathing becomes d
contaminated area imm
the respirator.
2. If used in environments
aerosols, replace after 4
days, whichever is first.
FOR MORE INFORMATION
In United States, contact:
Website: www.3M.com/Oc
Technical Assistance: 1-80
For other 3M products:
1-800-3M-HELPS or
1-651-737-6501
0515 IS-19189VND

Advertisement

loading

Summary of Contents for 3M P100

  • Page 1 Imprimé aux É.-U. observation of damaged or missing parts. 3M est une marque de commerce de la Compagnie 3M, utilisées sous licence au Canada. © 3M, 2010. Tous droits réservés. 7. Dispose of used product in accordance with applicable regulations.
  • Page 2: Directives D'utilisation

    Do not use for gases and vapors, asbestos or professional use by adults who are properly sélection des respirateurs de 3M sur le site exposition admissible ou sandblasting; particulate concentrations that trained in their use and limitations. This Web de la Division des produits d'hygiène...
  • Page 3 à 19,5%. ould respirador. comme l'uranium et le plutonium. Pour obtenir selección de respiradores 3M en el sitio Web de 2. Ne pas utiliser si les concentrations des 4. No use con barba u otro v des renseignements supplémentaires sur les la División OH&ESD de 3M...
  • Page 4: Para Obtener Más Información

    3. No altere ni maltrate ni haga mal uso de este clase de respirador favor de consultar la Guía de respirador. selección de respiradores 3M en el sitio Web de 4. No use con barba u otro vello facial u otra la División OH&ESD de 3M médiat...
  • Page 5 Fitting Instructions: Must be followed each time respirator is worn. 1. If not already threaded, thread 2. Pull the top strap over 3. Adjust the strap tension by 4. Place your fingertips from both hands at 5. Perform a User Seal Check prior to each wearing. the top elastic strap through your head, resting it pulling the straps as shown...
  • Page 6 1. PROTECTION obre la Filtre P100 contre les particules (niveau d’efficacité du filtre de 99,97%) efficace contre les aérosols contenant des particules. 2. AVERTISSEMENTS ET RESTRICTIONS A – Ne pas utiliser lorsque la concentration ambiante en oxygène est inférieure à 19,5%.

This manual is also suitable for:

8293