To Check The Version Of The Terminal Interface Software; If The Performance Verification Reports Massive Pv Failures; If The Emulator Appears To Be Malfunctioning - HP 64780A Installation/Service/Terminal Interface Manual

Emulator/analyzer
Hide thumbs Also See for 64780A:
Table of Contents

Advertisement

Chapter 6: Solving Problems

To check the version of the Terminal Interface software

To check the version of the Terminal Interface
software
• Type ver to display the version numbers of the Terminal Interface system software
and emulator software.
The MC68360 emulator firmware must be used with the correct version of the
emulation system and emulation analyzer firmware. See the paragraph titled, "To
ensure software compatibility" earlier in this chapter for more information.
If the Performance Verification reports massive
PV failures
Check to make sure mapper chip U84 on Emulation Control Card Subassembly
HP 64748C is installed properly in its socket.

If the emulator appears to be malfunctioning

Check to make sure that the cables connecting the Emulation Control Board to the
Emulation Probe are connected correctly.
Run the performance verification procedure as described in this chapter. If the
emulator fails this test, and if you upgraded your own emulation microprocessor to
use the Revision B silicon from Motorola, ensure that the software version of your
HP64780A Motorola 68360 Emulator is A.00.22, or higher software version
number. Then contact your Hewlett-Packard representative.
If the emulator passes the performance verification procedure, look for other
reasons for the problem. Performance Verification is a thorough test, but it cannot
find every hardware failure in the emulator. It is a good indication that the
116