Download Print this page
Delta 81T BTRKA DF Series Manual

Delta 81T BTRKA DF Series Manual

Electronic exposed teck ii flush valve retrofit kits (with h2optics)

Advertisement

Quick Links

Electronic Exposed
TECK
II Flush Valve
®
Retrofit Kits
(with H
Record model number:
81T__ __ BTRKA - __ __ - DF
Valve Type
WC = Water Closet
Part #
Description
Item #
1
061063A
Replaceable Lens for 3rd Generation E-FV
2
Cover Screws for 3rd Generation E-FV
061138A
Metal Cover
3
061139A
4
see #7
Electronic Button Head Assembly
5a
061140A
Case Top for 3rd Generation E-FV
5b
061170A
Plastic Case for 3rd Generation E-FV
6
Battery Holder
060334A
Water Closet Board and Electronic Override Button
7
061161A
8a
Regulating Screw & O-Ring
061024A
8b
061169A
Cast Cap/Solenoid & Regulating Screw Assembly
9a
061141A *
Cover Gasket (3/pkg)
060078A *
Screws for Cast Cap (4/pkg)
9b
10a
060507A
Water Closet Poppet Pin Pack (3/pkg)
061124A
10b
Thin Washer (6/pkg) (2 per valve required)
Diaphragm/Guide Assembly
11
061323A
Diaphragm Package
060079A-MMO
12
Brass Seat with O-ring
062007A
060342A
Plug and O-Ring for Handle End
13
061142A
Electronic Water Closet Repair Kit for 3rd Generation E-FV
14
15
061144A
Electronic Water Closet Repair Kit for DF 3rd Gen E-FV
16
061069A
Hardwire Converter & Rigid Connection Assy for 3rd Gen E-FV
061069A-BB
Hardwire Converter & Rigid Connection with Battery Back-up
17
060344A *
Filter Screen Kit (12/pkg)
060341A
Wrench for Brass Renewable Seat (ordered separately)
18
060704A
Transformer (110 to 24 VAC) for 5 Sensor Modules**
060771A
Transformer (110 to 24 VAC) for 10 Sensor Modules**
Transformer (110 to 24 VAC) for 25 Sensor Modules**
060772A
* Package Quantities May Change. Check the parts section of the latest Delta Commercial Faucet Price List for current quantities.
** Each individual sensor module requires its own 24 VAC to 6 VDC hardwire converter.
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as items
relating to ongoing maintenance suggestions and procedures are included.
Optics
)
2
Dual Flush Option
Flush Volumes
DF = dual flush
(leave blank - not applicable)
NOTE: For Hardwire versions, order battery operated model
with hardwire kit and transformer.
2
5a
7
1
10
a
10
b
11
12
13
For valves manufactured after January 2013.
w w w . s p e c s e l e c t . c o m
3
4
14
6
15
16
5b
9a
9b
8a
8b
18
17
Wrench for Brass
Renewable Seat
- for previous
Filter Screen
Flush Valve
models
(ordered
separately)
210381 Rev. A

Advertisement

loading

Summary of Contents for Delta 81T BTRKA DF Series

  • Page 1 - for previous Filter Screen Flush Valve * Package Quantities May Change. Check the parts section of the latest Delta Commercial Faucet Price List for current quantities. models (ordered ** Each individual sensor module requires its own 24 VAC to 6 VDC hardwire converter.
  • Page 2: Step 6: Operation Mode

    INSTALLATION INSTRUCTIONS - RETROFIT BATTERY FLUSHOMETER (For Hardwire Installation, see page 3.) REMOVE HANDS SHOULD BE CLEAN AND FREE OF GREASE AND OIL during any maintenance or handling of electronic housing components to prevent possible damage to internal circuitry. STEP 1: SHUT-OFF the water supply to the flushometer and inlet supply stop.
  • Page 3: Step 7: Set-Up Mode

    INSTALLATION INSTRUCTIONS - RETROFIT BATTERY FLUSHOMETER (cont’d) STEP 6: Operation Mode (cont’d) Factory pre-set functions are: WC bowl length of 24”, 24 hour flush is off, Dual Flush feature is on. INSTALLATION INSTRUCTIONS - HARDWIRED FLUSHOMETER STEP 1: to wall with centre of box in line with the cut-out in the back of the metal flush valve cover.
  • Page 4: Enter Setup Mode

    INSTALLATION INSTRUCTIONS - RETROFIT BATTERY FLUSHOMETER (cont’d) STEP 8: Making Adjustments (Optional: Only required if factory settings are not preferred) 8.2 Dual Flush Adjustment Mode: users do not sit, or are sitting for less than 90 seconds. Pressing the electronic override button while dual flush mode is ON will produce a full flush. To turn Dual Flush Mode ON - while in dual flush adjustment mode, press the electronic override button so that the middle red light is on.
  • Page 5: Cleaning Instructions

    BATTERY STRENGTH INDICATOR & BATTERY REPLACEMENT TO CHECK BATTERY STRENGTH: 1. During Operation Mode - press and hold down the electronic override button for approximately 10 seconds. 2. DO NOT RELEASE BUTTON WHEN SOLID BLUE LIGHT IS PRESENT - KEEP HOLDING DOWN. 3.
  • Page 6 NOTE: DO NOT USE EXCESSIVE FORCE to close the inlet stop stem. We RECOMMEND that the fllushometer be flushed while closing the inlet stop. The noise created by the water flow or the flow into the fixture will stop when the inlet water is shut off. NOTE: Always use DELTA COMMERCIAL GENUINE PARTS to maintain the warranty. EXCESSIVE NOISE: 1.
  • Page 7 Delta Commercial Faucet Limited Warranty All parts of the Delta® HDF® and TECK® faucets are warranted to the original consumer purchaser to be free from defects in material, finish and workmanship for a period of five (5) years unless otherwise specifically stated in the catalogue and price book. This warranty is made to the original consumer purchaser and shall be effective from date of purchase as shown on purchaser’s receipt.

This manual is also suitable for:

Teck ii