Oscillation Screen - Lincoln Electric APEX 3 Series Operator's Manual

Tig pendant
Hide thumbs Also See for APEX 3 Series:
Table of Contents

Advertisement

APEX
®
3 SERIES TIG PENDANT MANUAL

Oscillation Screen

The Oscillation Screen is used to test and adjust sys-
tem oscillation before welding. To enter, press and hold
the Dwell or Oscillation menu buttons while in the Jog
or Idle or Weld screens.
From the Idle screen, pressing and holding the Oscilla-
tor Menu Button will present the user with the option to
change the oscillation width and the oscillation speed.
From the Idle screen, holding down the Dwell Menu
Button will present the user with the option to change
the left and right dwells. In either screen, use a short
press to switch between Oscillation and Dwell. The
items highlighted in red are the variables that can be
changed.
Press the SWAP selection button to be taken to the
Travel Setup Screen.
Travel Setup is discussed in the Travel Setup Screen
section on page A-28. This screen allows the user to
quickly change weld head orientation or change the
weave pattern.
Press the "Exit" selection button to return to the Jog
Screens. Once all parameters have been input and
verified, exit out of the Jog Screen to return to the
Weld (also call the "Idle") Screen.