  • Page 1 IM3122 04/2020 REV01 ® ASPECT OPERATOR’S MANUAL ENGLISH Lincoln Electric Bester Sp. z o.o. ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland www.lincolnelectric.eu...
  • Page 2: Table Of Contents

    12/05 THANKS! For having chosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code & Serial Number can be found on the machine rating plate.
  • Page 3: Technical Specifications

    Technical Specifications NAME INDEX Aspect ® K14189-2 INPUT Input Voltage U EMC Class Frequency 115 - 240Vac ± 15% 50/60 Hz Input Line Mode 100% Input Amperes I PFmax 1max STICK 3.2 kW 1.9 kW 1.4 kW TIG DC 2.4 kW 1.8 kW 1.4 kW 115Vac...
  • Page 4: Electromagnetic Compatibility (Emc)

    If any electromagnetic disturbances are detected the operator must put in place corrective actions to eliminate these disturbances with, if necessary, assistance from Lincoln Electric. The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low-voltage supply system.
  • Page 5: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 6 CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. Always keep cylinders in an upright position securely chained to a fixed support. Do not move or transport gas cylinders with the protection cap removed.
  • Page 7: Introduction

    Introduction General Description Following paragraphs will show how to access to the menu and the parameters tha can be set. ASPECT ® 200 machine is designated to performe MMA following equipment been added (SMAW) and TIG (GTAW) welding process in DC and AC ®...
  • Page 8 Stick Welding (MMA) TIG Welding with a Water Cooled Torch This machine does not include a MMA welding kit cables, A cooling unit can be applied to the Machine: but may be purchased separately. Refer to the  COOLARC-24 accessories section for more information. If a Coolarc unit listed above is connected to the Machine, it will be automatically turned ON and OFF in order to First determine the proper electrode polarity for the...
  • Page 9 range. For further detail read the Error Codes and To restore the Machine restart to weld or push the Troubleshooting section. TIG trigger or push any buttons in the front panel or turn the encoder knob. If the trigger is pushed before the unit is ready to weld, or after a weld is completed in GTAW mode, the Power ON NOTE: If a COOLARC TIG torch cooling unit is LED will blink at a fast rate.
  • Page 10 Thermal LED: Output: This indicator will turn on when the machine is overheated and the output has been disabled. This normally occurs when the duty cycle of the machine has been exceeded. Leave the machine on to allow the internal components to cool.
  • Page 11 In Expert mode the following parameters are available: Pulse Sequencer Functions: 1. AC-Frequency: This function controls the frequency of the AC Wave shape in cycles per second. 2. AC-Balance: AC balance controls the amount of time, as a percentage, that the polarity is electrode negative.
  • Page 12 Memory Selection: Menu: The memory function is designed to allow the operator to save up to 9 specific welding procedures. This memory This unit permits an advance setting divided in 3 menu: button will have two functions: 1. Save memory settings 1.
  • Page 13 Operating Instruction AC Stick Welding To start AC Stick welding process: DC Stick (SMAW) Welding To start DC Stick welding process: 1. Set polarity 2. To select Stick welding: 1. Set polarity Process Visualization 2. To select Stick welding: Process Visualization Crisp Crisp...
  • Page 14 NOTE: The HF start strength is adjusted to the 2-Step Trigger Sequence tungstensize and type, which can be selected in menu To select 2-Step sequence: GTAW. Output Visualization AC Tig Welding To start AC Tig welding process: 1. Set polarity 2.
  • Page 15 4-Step Trigger Sequence To select 4-Step sequence: Output Visualization Press several times until the LED above lights up With the 4-step trigger mode and a TIG welding mode selected, the following welding sequence will occur. As shown above, it is possible to press and hold the TIG torch trigger a second time during downslope to end the downslope function and maintain the output current at the Crater current.
  • Page 16 As shown here, after the As shown here, after the TIG torch trigger is quickly TIG torch trigger is quickly pressed and released from pressed and released from step 3A, it is possible to step 3A, it is possible to press and hold the TIG press and hold the TIG torch trigger another time to...
  • Page 17 Bi-Level (Set/A2) Trigger sequence LIFT TIG ON sequence Enter Menu GTAW and enable BILV option. When lift tig process is selected, it is possible to performe When enabled, the bi-level tig function replaces the 4S welding operation without the use of a trigger. trigger sequence.
  • Page 18 List of parameters and Factory stored programs Table 6. List of parameters and Factory stored programs Displayed Displayed parameter Selectable Value Range value Factory Configuration name Function Default Current selected Preflow 0 - 25s (step 0.1s) value (s) STRT Current selected Starting Current 10 –...
  • Page 19 Note A: When AUTO is selected means 1s/10A; minimun Note D: Once AUTO is selected the default parameter are value is 3s. used. Note B: For frequency value higher than 500Hz, PEAK is Menu GTAW locked to 50%. To enter into Menu GTAW see section Menu, described above.
  • Page 20 Table 8. GTAW ADVANCED Menu Displayed Displayed Selectable Value Range parameter value Factory Configuration name Function Default SOFT SINE Current selected WAVE Wave Form SQRE value type SQRE AUTO (Note E) 0.5mm (0.02”) 1mm (0.04”) Current selected Tungsten size AUTO 1.6mm (1/16”) value 2.4mm (3/32”)
  • Page 21 Note E. When AUTO is selected, the starting parameters Following picture show the meaning of the parameter for a are automatically recalled based on the set current local hand working. The ramp in SSLP time ends when adjustable by main knob in the front panel. Diameter of STRT current level is reached: if STRT is lower than the electrode is automatically recalled based on the PCRT, the level will be PCRT.
  • Page 22 Menu SMAW To enter into Menu SMAW see section Menu, descriped above In AC polarity only the HOT Start parameter is visible and can be changed. Table 11. SMAW Menu Displayed Displayed Selectable Value Range parameter value Factory Configuration name Function Default SOFT: 35%...
  • Page 23 Table 12. SYS Menu Displayed Displayed Selectable Value Range parameter value Factory Configuration name Function Default Current selected UNIT Units mm / INCH value Current selected ON/OFF value Current selected LED Brightness/Intensity value HIGH FOOT Current selected RMTE TIG Remote Options value type Current selected UPDN...
  • Page 24 Please contact the nearest the possibility to select and change parameters as technical service center or Lincoln Electric and report the described in previous paragraphs. error code displayed on the meter of the Front Panel. UP/DOWN options...
  • Page 25 We respond to our customers based on the best Arc Time & Arc Counter information in our possession at that time. Lincoln Electric These two options show to the welder the total working is not in a position to warrant or guarantee such advice, hours and the total numeber of arc striking (max 9999).
  • Page 26: Weee

    12/05 Part List reading instructions  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.  Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.
  • Page 27: Suggested Accessories

    Suggested Accessories W000011139 KIT 35C50 W000382715-2 PROTIGIIIS 10RL C5B-S 5M W000382716-2 PROTIGIIIS 10RL C5B-S 8M W000382717-2 PROTIGIIIS 20RL C5B-S 5M W000382718-2 PROTIGIIIS 20RL C5B-S 8M W000382719-2 PROTIGIIIS 30RL C5B-S 5M W000382720-2 PROTIGIIIS 30RL C5B-S 8M W000382721-2 PROTIGIIIS 40RL C5B-S 5M W000382722-2 PROTIGIIIS 40RL C5B-S 8M W000382723-2...