Carrier 59SE5A Installation, Start-Up, Operating And Service And Maintenance Instructions page 29

Single stage 4-way multipoise condensing gas furnace 22vac 50 hz series 100

Advertisement

UNIT
SIZE
100-20
120-20
140-20
UNIT
SIZE
RETURN
AIR
CONNECTION
BOTTOM or
TWO-SIDES
3,4
BOTTOM
or
TWO-SIDES
3,4
BOTTOM or
TWO-SIDES
3,4
Table
9 - Air
Delivery
- CFM
(With
Filter)
WIRE
AIRFLOW
DELIVERY @ EXTERNAL STATIC PRESSURE
(in. w.c.)
COOLING
COLOR
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
TONS
CFM
Black
5
2260
2215
2165
2115
2065
2010
1950
1890
1825
1750
Blue
5
2140
2100
2050
2005
1960
1915
1855
1800
1740
1680
Yellow
4
1815
1775
1735
1690
1645
1600
1545
1490
1420
1405
Orange
3.5
1665
1625
1575
1535
1495
1455
1410
1355
1300
1245
Red
3.5
1515
1475
1435
1390
1350
1310
1260
1210
1160
1110
Black
5
2215
2160
2105
2050
1990
1925
1855
1785
1720
1655
Blue
5
2070
2020
1975
1920
1860
1800
1735
1675
1615
1560
Yellow
4
1770
1725
1680
1630
1570
1520
1465
1420
1370
1315
Orange
3.5
1595
1550
1505
1455
1410
1365
1315
1270
1215
1170
Red
3_65
,3_
270
_:38
_075
I
I
I
I
I
r
I
I
Black
5
2195
2145
2090
2035
1980
1915
1855
1795
1735
1675
Blue
5
2055
2005
1955
1905
1850
1795
1740
1685
1630
1575
Yellow
4
1755
1710
1660
1610
1565
1515
1465
1415
1365
1310
WIRE
AIRFLOW
DELIVERY @ EXTERNAL STATIC PRESSURE
(in. w.c.)
0.1
0.2
0.3
0.4
0.5
0.7
0.8
RETURN
AIR
CONNECTION
BOTTOM or
100-20
TWO-SIDES
3,4
810
780
760
735
BOTTOM or
120-20
645
620
TWO-SIDES
3,4
570
550
COOLING
COLOR
TONS
Black
5
Blue
5
Yellow
4
Orange
3.5
Red
3.5
Black
5
Blue
5
Yellow
4
Orange
3.5
0.6
L/s
1065
1045
1020
995
970
945
920
890
1005
990
965
945
925
900
875
845
855
835
815
795
775
755
725
700
785
765
740
720
705
685
665
635
715
695
675
655
635
615
590
570
1045
1015
990
965
935
905
875
840
975
950
930
905
875
845
815
790
835
810
790
765
740
715
690
670
750
730
710
685
665
640
620
595
0.9
1
860
825
820
790
670
660
610
585
545
520
iiiiiiiiiiiiiiiiiiiiiiiiiiii!iii!iiiii!ii!ii!iiiiiiii!!!ii!i!iii
¸¸¸¸¸¸¸¸¸¸¸¸¸¸¸¸
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII__
___I_
__
................................
_!_!_
....................
Black
5
1035
1010
985
960
930
900
875
845
815
790
Blue
5
965
945
920
895
870
845
820
795
765
740
BOTTOM or
140-20
Yellow
4
825
805
780
755
735
715
690
665
640
615
TWO-SIDES
3,4
635_
_95
57_
55_
:
75
NOTE:
1. A filter is required for each return-air
inlet.
Airflow performance
includes a 3/4-in.
(19 mm) washable
filter media such as contained
in a factory-authorized
accessory filter rack. See accessory
list. To determine
airflow performance
without this filter, assume an additional
0.1 in. w.c.. available
external static
pressure.
2. Blower speed taps are not always in the same order.
Factory default blower connections
are as follows:
a. Heating airflow - BLUE (also used for Continuous
Fan)
b. Cooling airflow - BLACK (enabled when the Y terminal
is energized)
ADJUST THE BLOWER
SPEED TAPS AS NECESSARY
FOR THE PROPER AIR TEMPERATURE
RISE FOR EACH INSTALLATION.
3. Airflows over 1800 CFM require bottom return, two-side
return, or bottom and side return.
A minimum filter size of 20" x 25" (508 x 635 mm) is required.
4. For upflow applications,
air entering
from one side into both the side of the furnace and a return air base counts as a side and bottom return.
5. Highlighted
areas indicate that this airflow range is beyond
the range allowed
for heating.
THESE AIRFLOW RANGES
MAY ONLY BE USED FOR COOL-
ING.
29