Carrier Comfort 59SC5A Series Product Data

Carrier Comfort 59SC5A Series Product Data

Comfort series single-stage 4-way multipoise condensing gas furnace series 100

Advertisement

59SC5A
Comfort™ Series Single---Stage
4---Way Multipoise
Condensing Gas Furnace
Series 100
The 59SC5 Multipoise Comfort Series Condensing Gas Furnace
features energy efficiency of 95.5% AFUE gas efficiency and
workhorse PSC blower motor. This gas furnace also features
4-way multipoise installation flexibility, and is available in nine
model sizes. The 59SC5 can be vented for direct vent/two-pipe,
ventilated combustion air, or single-pipe applications. All units
meet California Air Quality Management District emission
requirements, are design certified in Canada, and are certified for
mobile/manufactured home use.
STANDARD FEATURES
S 4-way multipoise design for upflow, downflow or horizontal
Product Data
installation.
S Installation flexibility with a 360-degree rotating elbow.
S More than twelve different venting options, including optional
through-the-cabinet downflow and horizontal venting.
S Ideal condensing furnace height 35" (889 mm) cabinet: short
enough for taller coils, but still allows enough room for service.
S Silicon Nitride Power Heatt Hot Surface Igniter.
S Aluminized-steel primary heat exchanger.
S Stainless-steel condensing secondary heat exchanger.
S High-quality corrosion-resistant prepainted steel cabinet with
hemmed edges for safety.
S Factory-configured ready for upflow applications.
S Direct-vent/sealed combustion, single-pipe venting or ventilated
combustion air.
S PSC blower motor, single-speed inducer motor, and single-stage
gas valve.
S Self-diagnostics with SuperBrite LED.
A11263
S Approved for Twinning applications (040- -12 through 120-20
sizes, only).
S Propane convertible (See accessory list).
S Approved for Manufactured Housing/Mobile Home applications
(except 140,000 Btuh input) with MH accessory kit.
S Convenient Air Purifier and Humidifier connections.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1- -in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
Use of the AHRI Certified
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
1
Mark indicates a
TM
CERTIFIED

Advertisement

Table of Contents
loading

Summary of Contents for Carrier Comfort 59SC5A Series

  • Page 1 59SC5A Comfort™ Series Single---Stage 4---Way Multipoise Condensing Gas Furnace Series 100 Product Data installation. S Installation flexibility with a 360-degree rotating elbow. S More than twelve different venting options, including optional through-the-cabinet downflow and horizontal venting. S Ideal condensing furnace height 35” (889 mm) cabinet: short enough for taller coils, but still allows enough room for service.
  • Page 2: Features And Benefits

    Power Heatt Igniter — Carrier’s unique SiN igniter is not only Monoport Burners — The burners are specially designed and physically robust but it is also electrically robust. It is capable of...
  • Page 3: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 040-10 040-12 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20 High Input (BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000 Heat High Output (BTUH) 39,000 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000 Heat...
  • Page 4: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Example of Model Number 1 - 2 7 - 9 11 - 12 15 - 16 Family Htg. Stages Tier Major Series Htg. Cap. Motor Width Base Effy. Voltage Minor Series Airflow 08 - 800 CFM Family 10 - 1000 CFM 12 - 1200 CFM S - Single Stage...
  • Page 5 ACCESSORIES DESCRIPTION PART NUMBER 040--- 10 060--- 10 040--- 12 060--- 14 080--- 16 080--- 20 100-14 100-20 120-20 140-20 Venting Accessories Vent Kit - Through the Cabinet KGADC0101BVC Vent Terminal - Concentric - 2” (51 mm) KGAVT0701CVT Vent Terminal - Concentric - 3” (76 mm) KGAVT0801CVT See Venting Tables Vent Terminal Bracket - 2”...
  • Page 6 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) EXTERNAL STATIC PRESSURE (IN. W.C.) RETURN-AIR SPEED UNIT SIZE CONNECTION TAPS Black 1100 1055 1010 Yellow 040---10 SIDE/BOTTOM Blue Black 1245 1195 1150 1100 1050 1000 Yellow 1165 1120 1075 1030 040---12 SIDE/BOTTOM Orange...
  • Page 7 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 1 – Maximum Equivalent Vent Length - - Ft. (M) 0 to 4500 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 8: Manufacturer's Instructions

    Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 2. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems.
  • Page 9 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) (CONTINUED) Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 10 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) Insulation 1/2-in. (12.7 mm) Insulation Single Stage Pipe Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Winter Design Furnace Length in...
  • Page 11: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 12 Carrier cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 13: Typical Wiring Schematic

    MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots Media Filter (146mm) Cabinet 17" (432mm) 16" (406mm) 16" (406mm) 20" (508mm) 21"...
  • Page 14: Dimensional Drawing

    DIMENSIONAL DRAWING A12267 59SC5 SHIP WT. LB (KG) FURNACE SIZE CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 040--- 10 123.0 (55.4) 14--- 3/16 (361) 12--- 1/2 (319) 12--- 9/16 (322) 7--- 1/8 (181) 060--- 10 127.0 (57.2) 040--- 12 134.0 (60.9) 060--- 14 17--- 1/2 (445)
  • Page 15: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane).
  • Page 16 Catalog No: 59SC5A ---03PD Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 10/12 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: 59SC5A--- 02PD...

Table of Contents