Blower Replacement - Napoleon Castlemore GDS26P-1 Installation And Operation Manual

Hide thumbs Also See for Castlemore GDS26P-1:
Table of Contents

Advertisement

Available languages

Available languages

WARNING
!
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan's power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.
ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and
grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the current ANSI/NFPA 70 National Electrical Code in the United States.
1. Disconnect the gas and power supply.
2. Remove the 4 screws securing the blower mounting plate to the appliance.
3. Disconnect the 2 fl ag connectors and the grounding wire.
4. Remove the screws securing the blower to the mounting plate.
5. Install the new blower by securing it to the mounting plate using screws from step 4.
6. Reconnect the 2 fl ag connectors and the grounding wire to the new blower.
7. Resecure the blower mounting plate to the appliance using the 4 screws removed in step 2.
8. Reconnect the gas and power power supply.
WIRING DIAGRAM
BLOWER
BLACK
WIRE
HARNESS
GREEN
(GROUND)
TO
IPI
CONTROL

6.0 blower replacement

BLOWER
ASSEMBLY
W415-2360 / A / 10.31.19
EN
GROUND
SCREW