7.4

temperature display

A. With the system in the off position, press the Temperature Key and the
mode key at the same time to change from degrees F to C.
B. Look at the LCD screen on the transmitter to verify that a C or F is
visible to the right of the Room Temperature display.
7.5
fl ame height
The remote control has six (6) fl ame levels. With the system on and the fl ame level at the maximum, press the Down
arrow key once and it will reduce the fl ame height by one step until the fl ame is turned off.
The Up Arrow Key will increase the fl ame height each time it is pressed. If the Up arrow key is pressed while the
system is on but the fl ame is off, the fl ame will come on at the high position. A single "beep" will confi rm reception of
the command.
7.6

blower speed

If the appliance is equipped with a hot air circulating fan, the speed of the
fan can be controlled by the remote system. The fan speed can be adjusted
through six (6) speeds.
A. Use the mode key to guide you to the fan control icon.
B. Use the mode key to turn on/off or adjust the fan speed. A single
"beep" will confi rm reception of the command.
note:
When the desired blower speed is selected, the blower will automatically come on 5 minutes after the main
burner has been turned on and remain on twelve minutes after it has been turned off.
7.7

night light dimmer control

ADD TITLE: Night Light Dimmer Control
The auxiliary function controls the Night Light
A. Use the Mode Key to guide you to the Night Light icon.
B. The intensity of the output can be adjusted through 6 levels.
Use the UP/DOWN arrow keys to adjust the output level.
single beep will confi rm reception of the command.
7.8

continuous pilot / intermittent pilot (CPI / IPI) selection

A. When the transmitter is in the "OFF" position, use the Mode Key to guide
you to the CPI mode icon.
B. Press the UP/DOWN to switch between IPI and CPI modes. A single BEEP
will confi rm reception of the command.
note:
If the appliance is equipped with a CPI/IPI toggle switch, set the switch to CPI
position to enable remote CPI operation. If the switch is set to IPI then it will
only work in IPI regardless of what is set on the remote control handset.
76
76
°F
OFF
Flame Off
Flame at level 1
TM
with dimmable control.
operation
°F
73
76
°F
°F
Flame at level 5
Flame at "Hi" level 6
76
°F
68
76
°F
OFF
A
76
°F
IPI
CPI
W415-2360 / A / 10.31.19
EN
°C
23
76
°F
Hi
76
°F
Hi
76
°F
76
°F
39