AC Power Wiring
Complete all wiring to the control panel before connecting AC
power or the battery. Do not plug the transformer into an
outlet that is controlled by a switch.
AC
50 OR 60 Hz
Battery Connection
If the battery is reverse connected, the 5 A fuse will blow. The
battery charging voltage is factory set and normally needs no
adjustment. If the battery charging voltage is out of adjustment,
contact your service representative.
NOTE: The PC1510 will not power up, even with a fully
charged battery, until AC power is connected. After an
extended AC power failure, the battery will be automatically
disconnected when its voltage drops to between 9 V and 10
V. This feature is designed to prevent damage to the battery
due to deep discharging.
BATTERY CHARGE CURRENT
IS 360 mA MAX
+
12 VOLT 4 Ah.
GEL - CELL
BATTERY CAPACITY FOR
EMERGENCY STANDBY
IS AT LEAST 4 HOURS IF
THE TOTAL LOAD (BELL
AUX OUTPUTS) IS 800 mA
OR LESS
4
16VAC
40 VA MIN
CSA LISTED
TRANSFORMER
RED
BLK
-
Telephone Line Wiring
R-1 T-1 RNG TIP
Do not connect the alarm panel communicator to telephone
lines intended for use with facsimile (fax) machines. These
lines may incorporate a voice filter which disconnects the
line if other than fax signals are detected. This may result
in incomplete transmissions from the alarm panel
communicator.
GRN
RED
RJ31-X
TELEPHONE
BRN
PLUG
GRY