Maintenance Alarms and Restorals
For automatic test code reporting, time between reports (in days) must be specified in Section [17], and time of
day for the report must be entered in Section [19].
Low Battery Alarm
AC Fail Alarm
Fuse Failure Alarm
Low Battery Restore
AC Fail Restore
Fuse Failure Restore
Automatic Test Code
[11]
Zone Definitions
NOTE: When defining zones, assign delay zones first to zones 1,2,3..., then assign the other zone types to the
remaining zones in any order desired.
Default
0 0
0 1
0 1
0 2
0 2
0 8
[12]
1st System Option Code
Default
OFF
Zone Light 1
OFF
Zone Light 2
ON
Zone Light 3
ON
Zone Light 4
OFF
Zone Light 5
ON
Zone Light 6
22
Page 12
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Page 13
Zone Light ON
Communicator disabled
TX limit to 24 hour period
Alarm display while armed
DTMF dialling
N.C. loops (except fire)
Keypad [P]anic audible (bell)
Page 12
First Digit
0 = Slow, Audible
1 = Slow, Silent
2 = Fast, Audible
3 = Fast, Silent
• • • • • Any one zone may be set as a FIRE zone.
Zone Light OFF
Communicator enabled
TX limit to armed period
No alarm display while armed
Pulse dialling
EOL resistor loops
Keypad [P]anic silent (bell)
PC1510 Version 4.1
Second Digit
0 = Standard Delay
1 = Instant
2 = Interior
3 = Interior, Home-Away
4 = 24 Hour Bell
5 = 24 Hour Bell/Buzzer
6 = 24 Hour Buzzer
7 = Aux. Delay (Uses Auxiliary
Entry/Exit Times)
8 = Fire•