[32] 5th System Option Code
Use the same method of programming as section [12].
ZONE
LIGHT
[1]
ON = Loss of AC will not cause an AC trouble
• OFF = Loss of AC will cause AC trouble
[2]
ON = No bell during Auto-Arm (burst every 10
seconds is silenced)
• OFF = 1 burst of bell / siren every 10 seconds
during Auto-Arm pre-alert
[3]
• ON = Home-Away zones will have an entry
delay when tripped
OFF = Home-Away zones act as interior when
tripped
[4]
ON = Quick-Exit is enabled ([
1 transition of a delay zone)
• OFF = Quick-Exit is disabled
[5]
ON = Auxiliary delay loops can be force armed
• OFF = Auxiliary delay loops cannot be force
armed
[6]
• ON = Standard Fire – Fire alarms will pulse bell
OFF = Temporal Fire – Fire alarms will sound bell
using the temporal fire pattern
Temporal fire pattern:
0.5 sec. ON, 0.5 sec. OFF,
0.5 sec. ON, 0.5 sec. OFF,
0.5 sec. ON, 1.5 sec. OFF.
• Factory default
[33]
Answering Machine Double Call
Timer
This location sets the amount of time between calls when
using the answering machine over-ride feature. See section
[31], light 3.
[34]
6th System Option Code
Use the same programming method as in Section [12].
ZONE
LIGHT
[1]
ON = Audible Exit Delay with urgency
• OFF = Standard Exit Delay
[2]
ON = Bell Squawk during Exit Delay
• OFF = No Bell Squawk during Exit Delay
[3]
ON = Audible Exit Fault enabled
• OFF = Audible Exit Fault disabled
[4]
ON = Urgency applied to Entry Delay
• OFF = Standard Entry Delay
[5]
ON = Bell Squawk during Entry Delay
• OFF = No Bell Squawk during Entry Delay
[6]
ON = [F] Key disabled
• OFF = [F] Key enabled
• Factory default
When Light 3 is ON (Audible Exit Fault):
system is armed and a Standard Delay Zone is left open at
18
the end of the Exit Delay, the bell/siren will sound a steady
tone for the duration of the Entry Delay.
Entry and Exit Delay Urgency:
option is selected for the audible Entry Delay, the keypad
will sound a constant tone during the Entry Delay. During
the last 10 seconds of the Entry Delay, the keypad will
sound a pulsing tone to warn that the delay is about to
expire.
When the urgency option is selected for the audibile Exit
Delay, the keypad will sound a pulsing tone during the Exit
Delay. During the last 10 seconds of the Exit Delay, the
keypad will sound a faster pulsing tone to warn that the delay
is about to expire.
][0] ignores
[35]
This Section is not used by the PC1510 Version 4.1 Software;
do not program this section.
[36]
Program two 2-digit numbers in this section.
The first entry determines how many invalid codes may be
entered before the keypad is locked out and will not accept
any further entries. Program a number from 00 to 99; 00
disables the keypad lockout function.
The second entry determines how long, in minutes, the
keypad will be locked out once the programmed number
of invlaid codes are entered. Program a time from 00 to
99 minutes.
[90]
This feature is enabled by entering [90] while in the installer's
programming mode. A factory default (hardware or software)
will not reset the installer's code or the download access
code once this feature is enabled. A panel that has this
feature enabled will give a distinct audible indication upon
power-up. This indication is the phone line relay clicking 10
times. Make sure that your new installer's code has been
entered correctly before enabling this feature because there
is no way of re-entering the programming mode without the
new installer's code. Remember that even a reset to the
factory default will not change the installer's code back to the
default.
[91]
Entering [91] when in the installer's programming mode will
disable the installer's lockout feature.
NOTE: Panels returned to DSC with the installer's lockout