Canon NP-70 Service Manual page 45

Table of Contents

Advertisement

NP-70
3-3
No.
Symbol
Description
Function
6
HV (AC)
High Voltage
Transformer
Develops High Voltage AC for
,
Coronas
HV
HV (DC)
High Voltage
Develops High Voltage DC for
Coronas
7
~
~
ST 1
Stabilizer
For Lighting FL 1 (except 100VAC
Line Voltage)
8
~~
~
ST2
Stabilizer
For Lighting FL2 & FL3
9
~
s
<s
'
--- s
ES
Stabilizer
For Lighting FL 1 (100VAC Line
Voltage only)
10
FS
Temperature-
sensitive Fuse
Prevention of Excessive Temperature
Rise inside the Heater Assembly
(melts at 150°C)
~9
I 1
FL 1
Fluorescent Lamp
Overall Exposure (1 OW)
^
^
FL2.3
Fluorescent Lamp
Original Exposure (25W)
12
PL2
Pilot Lamp
(Neon Lamp)
"Paper Jam" Indication (Line AC
voltage)
PLS
Pilot Lamp
(Neon Lamp)
ON/OFF Indication (line AC voltage)
13
PL1
Pilot Lamp
(Tungsten Lamp)
"Ready" Indication (+24VDC)
PL3
Pilot Lamp
(Tungsten Lamp)
"Developer Supply" Indication
(+24VDC)
PL4
Pilot Lamp
(Tungsten Lamp)
"Paper Supply" Indication
(+24VDC)