TO ADJUST THE CLEARANCE BETWEEN NEEDLES
Correct Setting:
The clearance between needle and the fixed needle guard should be 0.1 to 0.4 mm.
To adjust:
1. Remove the foot and the needle plate and lower the needle to its lowest position.
2. Loose the setscrew A and adjust the position of the fixed needle guard.
3. Tighten the setscrew A.
4. Attach the needle plate and the foot.
Chaining finger
(Needle plate setting knob is to be "S")
Chaining finger
Fixed needle guard
AND FIXED NEEDLE GUARD
Setscrew A
Needle plate setting knob
The clearance between the needle and
fixed needle guard
Fixed needle guard
To be touch
18
0.1 ~ 0.4 mm
Tip of fixed needle guard