TO ADJUST THE PRESSER BAR HEIGHT

Correct Setting:
The distance between the surface of needle plate and bottom of presser foot should be 4.7 to 5.3 mm (47/254
to 53/254") when the presser bar lifter is raised.
To adjust:
1. Remove the face plate unit.
2. Remove the setscrew A to move the lamp socket unit.
3. Raise the presser bar lifter, and loosen the setscrew B.
Then adjust the presser bar height, the side of presser foot should be parallel with the hole of needle plate.
4. Tighten the setscrew B.
5. Tighten the setscrew A.
6. Attach the face plate unit.
Lamp socket unit
4.7 ~ 5.3 mm
Presser bar lifter
Setscrew A
(3 pcs)
To be parallel
Top surface of needle plate
10
Setscrew B
(Direction of presser foot)