Operation
Functions
Logical AND Connection
● Example with G9SX-AD322-@
The logical AND connection means that the Basic Unit (or Advanced
Unit) outputs a safety signal "a" to an Advanced Unit, and the
Advanced Unit calculates the logical multiplication (AND) of the safety
signal "a" and safety signal "b." The safety output of an Advanced Unit
with the logical AND connection shown in the following diagram is "a"
AND "b".
a
Basic Unit
G9SX-BC202-@
a
This is illustrated using the application in the following diagram as an
example. The equipment here has two hazards identified as Robot 1
and Robot 2, and it is equipped with a safety door switch and an
emergency stop switch. You may have overall control where both
Robot 1 and Robot 2 are stopped every time the emergency stop
switch is pressed. You may also have partial control where only
Robot 1, which is closest to the door, is stopped when the door is
opened. In that case, Robot 2 will continue to operate.
The actual situation using a G9SX for this application is shown in this
example.
(Note: The logical AND setting on the Advanced Unit must be set to
AND (enabled).)
Robot 2
Emergency stop Switch
a
Basic Unit
Robot 2
b
Advanced Unit
G9SX-AD322-@
a (AND) b
Robot 1
Emergency
stop Switch
Safety Door
Switch
Door Switch
b
Advanced Unit
Robot 1
● Example with G9SX-ADA222-@
The Advanced Unit G9SX-ADA222-@ is equipped with two logical
AND connection inputs. Therefore, it is capable of receiving two
safety signals, each from different Advanced or Basic Units. As
shown in the diagram below, the output of Advanced Unit
G9SX-ADA222-@ will be "a" AND "b" AND "c".
a
Basic Unit
G9SX-BC202-@
a
Basic Unit
G9SX-BC202-@
Connecting Expansion Units
• The G9SX-EX and G9SX-EX-T Expansion Units can be connected
to an Advanced Unit (G9SX-AD322-@/G9SX-ADA222-@) to
increase the number of safety outputs. (They cannot be connected
to a Basic Unit.)
• A maximum of five Expansion Units can be connected to one
Advanced Unit. This may be a combination of G9SX-EX
Instantaneous types and G9SX-EX-T OFF-delayed types.
• Remove the terminating connector from the receptacle on the
Advanced Unit and insert the Expansion Unit cable connector into
the receptacle. Insert the terminating connector into the receptacle
on the Expansion Unit at the very end (rightmost).
• When Expansion Units are connected to an Advanced Unit, make
sure that power is supplied to every Expansion Unit. (Refer to the
following diagram for actual Expansion Unit connection.)
T31
T32
T33
13
23
33
43
T11
T12
Y1
X1
X2
A1
G9SX-AD322-T15
G9SX-EX
24VDC
PWR
FB
PWR
T1
T2
ED
AND
EI
ED
1.5
1
2
0.7
3
0.6
4
0.5
5
0.4
7
ERR
0.3
10
0.2
15
0
No.
No.
OFF-DELAY
T21
T22
T41
T42
A2
A1
X2
A2
S14
S24
S34
S44
S54
L1
14
24
34
44
Advanced Unit
G9SX
c
b
Advanced Unit
G9SX-ADA222-@
a AND b AND c
b
13
23
33
43
13
23
33
43
13
23
33
43
13
23
33
43
G9SX-EX
G9SX-EX
G9SX-EX
G9SX-EX
24VDC
24VDC
24VDC
24VDC
PWR
PWR
PWR
PWR
ED
ED
ED
ED
Terminating
connector
No.
No.
No.
No.
A1
X2
A2
A1
X2
A2
A1
X2
A2
A1
X2
A2
14
24
34
44
14
24
34
44
14
24
34
44
14
24
34
44
Expansion Unit
11

Advertisement

loading