FX
Series Programmable Controllers
3G
User's Manual - Hardware Edition
17.2
Specifications
17.2.1 Generic Specifications
The generic specifications are the same as those for the main unit.
17.2.2 Performance Specifications
Supply voltage
Voltage fluctuation range
Rated frequency
Allowable instantaneous power failure time
Rush current
Power consumption
Output current
(Internal for supply)
*1. The output current depends on the ambient temperature as shown in the derating curve below.
17.2.3 External Dimensions
2- 4.5 mounting holes
4(0.16")
55(2.17")
288
Items
100-240V AC
-15%, +10%
50/60Hz
The allowable momentary power failure time depends on the power supply used.
•
•
30A max. 5ms or less/100V AC, 65A max. 5ms or less/200V AC
20W Max.
24V DC
300mA
5V DC
1000mA
Output current [mA]
1000
800
300
200
Unit:mm (inches)
87(3.43")
→ For the generic specifications, refer to Section 4.1.
100V AC power supply system:
The operation is continued to the momentary power failure for 10 or less ms.
200V AC power supply system:
The operation is continued to the momentary power failure for 100 or less ms.
*1
*1
Derating curve
5V DC
24V DC
0
40
55
Ambient temperature [°C]
9(0.36")
17 Extension Power Supply Unit
17.2 Specifications