External Dimensions - Mitsubishi Electric MELSEC-F FX3G Series User Manual

Hide thumbs Also See for MELSEC-F FX3G Series:
Table of Contents

Advertisement

FX
Series Programmable Controllers
3G
User's Manual - Hardware Edition
3. Output specifications (relay output type)
Item
Output Points
Connection type
Output unit
External power supply
Output circuit insulation
Indication of output operation
Max. load
Open circuit leakage current
Min. load
Response time
Output circuit configuration

15.5.2 External dimensions

FX
-32ER
2N
2- 4.5 mounting holes
140 (5.52") (mounting hole pitch)
238
The total load current per common terminal
Resistance load
should be the following value.
8 output points/common terminal: 8A or less
Inductive load
OFF ON
ON OFF
150 (5.91")
15 Input/Output Powered Extension Units
15.5 FX2N-32ER, FX2N-48ER, FX2N-48ER-D
FX
-32ER
2N
16 points
Removable terminal block (M3 screw)
Relay
250V AC/30V DC or less
Mechanical insulation
When power is applied to relay coil, LED is lit.
2A/point
The total load current per common terminal
should be the following value.
80VA
→ For the product life, refer to Subsection 14.4.3.
→ For cautions on external wiring, refer to Subsection 12.1.3.
-
5V DC, 2mA (reference value)
Approx. 10ms
Approx. 10ms
Load
Y
DC power
supply
COM
Fuse
Y
External
power supply
COM
Fuse
A common number applies to the of [COM ].
Unit : mm (inches)
87 (3.43")
FX
-48ER, FX
-48ER-D
2N
2N
24 points
2A/point
4 output points/common terminal: 8A or less
8 output points/common terminal: 8A or less