Clean-Up for ThermoLazer 200/200TC/300TC

Clean-Up for ThermoLazer 200/200
BURN HAZARD
Never scoop out remaining melted thermoplastic from
kettle. Remaining thermoplastic can be left to harden
inside the kettle and can be remelted at a later date.
1. Secure ThermoLazer by chocking wheels.
2. Use scraper to clean out trough and screed box.
34
Be sure to thoroughly clean all material out of screed
box and any open areas to prevent material from freez-
ing moving parts of screed box. Always run all material
out of each screed box before removing. Scrape out all
remaining material before it sets within the screed box.
To prevent material from hardening and blocking flow,
scrape all excess material off of external surfaces after
each use, including the material trough.
Remove any remaining beads in the bead hopper and
bead dispenser to prevent beads from clogging hopper
and dispenser.
ti14603a

Transporting

Remove LP-Gas supply cylinder from ThermoLazer
before transporting. Secure in an approved location and
method as authorized by local, state, federal, national,
and international agencies.
Always use the designated mounted lifting lugs when
lifting the Thermolazer. When lifting the Thermolazer
only use ANSI approved slings and equipment rated for
a minimum of 2000 lb. Always use ANSI approved
equipment for securing ThermoLazer to transporting
equipment.
ti14529a
/300
TC
TC
NOTICE
NOTICE
NOTICE
3A1319K