Lighting Instructions

Lighting Kettle Burners

NOTE: Read Important Safety Information, page
14-16.
ThermoLazer 200
1. Open kettle door to view burner.
2. Open propane tank valve.
ti14127a
3. Open kettle temperature control knob (AA).
4. Light kettle burner with torch.
5. Regulate kettle flame as desired with kettle tem-
perature control knob (AA).
3A1319K
ti23087a
ti23095a
ti23096a
FIRE AND EXPLOSION HAZARD
If pilot ignites without depressing the gas safety valve
knob, replace gas safety valve. If gas safety valve
knob does not pop back after releasing in pilot posi-
tion, STOP and replace gas safety valve. Shut off gas
at propane tank before replacing valve.
6. Turn gas safety valve knob to "ON".
7. Turn temperature to 250° F (121° C) and observe
that main burners have ignited. Turn kettle
temperature control back to "OFF" and observe that
main burners shut off.
FIRE AND EXPLOSION HAZARD
If main burners do not ignite or shut off when rotating
temperature control knob, STOP. Shut off gas at the
propane tank. Follow diagnostic procedure in Repair
manual.
8. Turn temperature control to desired setting.