Preparing Thermolazer 200/200Tc/300Tc For Application - Graco ThermoLazer 200 Operation

Pavement marking systems
Hide thumbs Also See for ThermoLazer 200:
Table of Contents

Advertisement

Preparing ThermoLazer 200/200
BURN HAZARD
Keep all access covers closed and latched when equip-
ment is in use.
Always secure ThermoLazer by chocking wheels when
adding thermoplastic.
1. Secure the unit by chocking wheels and applying
parking brake.
2. Make sure kettle burners and screed box burners
are lit.
3. Allow kettle to heat up before adding material. If ket-
tle is completely empty, allow kettle to reach
300° - 350° F (149° - 177° C) before adding mate-
rial. If kettle has material, allow material to reach
380° F (193° C) before adding material.
4. Secure ThermoLazer by chocking wheels.
5. Add thermoplastic material to kettle.
3A1319K
ti14603a
ThermoLazer 300
shown
TC

Preparing ThermoLazer 200/200TC/300TC for Application

/
300
for Application
TC
TC
6. Move Gate Valve Actuator (S) to raised position and
fill screed box with melted thermoplastic material.
S
NOTE: The material gate is adjustable. The gate is
factory set at a 0.5 in. (1.3 cm) gap. You can
increase this gap for more material flow or decrease
the gap for less material flow.
7. Do not overfill material in kettle. Overfill would be
material higher than 5 in. (13 cm) below top of ket-
tle.
Overfill
Line
8. Close and latch cover access doors when applying
thermoplastic.
9. Avoid bumping or impacting Thermolazer to prevent
spillage or splashing of hot material.
ti14122b
0.5 in.
ti14123a
5.0 in.
ti14410a
29