Process Interrupt; Diagnostic Interrupt - YASKAWA VIPA System 300S+ Manual

Hide thumbs Also See for VIPA System 300S+:
Table of Contents

Advertisement

Deployment I/O periphery
Counter - Diagnostic and interrupt > Diagnostic interrupt
6.13.1

Process interrupt

Function
6.13.2

Diagnostic interrupt

Function
132
A process interrupt causes a call of the OB 40. Within the OB 40 you may find the logical
basic address of the module that initialized the process interrupt by using the local word
6. More detailed information about the initializing event is to find in the local double word
8.
The local double word 8 of the OB 40 has the following structure:
Local byte
Bit 7...0
8
n
Bit 0: Edge at I+0.0
n
Bit 1: Edge at I+0.1
n
Bit 2: Edge at I+0.2
n
Bit 3: Edge at I+0.3
n
Bit 4: Edge at I+0.4
n
Bit 5: Edge at I+0.5
n
Bit 6: Edge at I+0.6
Bit 7: Edge at I+0.7
n
9
n
Bit 0: Edge at I+1.0
n
Bit 1: Edge at I+1.1
n
Bit 2: Edge at I+1.2
Bit 3: Edge at I+1.3
n
n
Bit 4: Edge at I+1.4
n
Bit 5: Edge at I+1.5
n
Bit 6: Edge at I+1.6
n
Bit 7: Edge at I+1.7
10
Bit 0: Gate counter 0 open (activated)
n
n
Bit 1: Gate counter 0 closed
n
Bit 2: Over-/underflow/end value counter 0
n
Bit 3: Counter 0 reached comparison value
n
Bit 4: Gate counter 1 open (activated)
n
Bit 5: Gate counter 1 closed
n
Bit 6: Over-/underflow/end value counter 1
n
Bit 7: Counter 1 reached comparison value
11
n
Bit 0: Gate counter 2 open (activated)
n
Bit 1: Gate counter 2 closed
n
Bit 2: Over-/underflow/end value counter 2
n
Bit 3: Counter 2 reached comparison value
n
Bit 4: Gate counter 3 open (activated)
n
Bit 5: Gate counter 3 closed
n
Bit 6: Over-/underflow/end value counter 3
Bit 7: Counter 3 reached comparison value
n
Via the parameterization (record set 7Fh) you may activate a global diagnostic interrupt
for the module. A diagnostic interrupt occurs when during a process interrupt execution in
OB 40 another process interrupt is thrown for the same event. The initialization of a diag-
nostic interrupt interrupts the recent process interrupt execution in OB 40 and branches in
OB 82 to diagnostic interrupt processing
cessing other events are occurring at other channels that may also cause a process res.
diagnostic interrupt, these are interim stored. After the end of the diagnostic interrupt pro-
. If during the diagnostic interrupt pro-
incoming
HB140 | CPU | 314-6CF23 | en | 19-01
+
VIPA System 300S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Speed7 cpu-sc 314-6cf23Cpu 314st

Table of Contents