Advertisement

Quick Links

Quick Guide for
ENC-G5
09/22/2022
Revision 1

Advertisement

Table of Contents
loading

Summary of Contents for YASKAWA ENC-G5

  • Page 1 Quick Guide for ENC-G5 09/22/2022 Revision 1...
  • Page 2: Table Of Contents

    Table of Contents Product Features Product Specifications -- -- Datasheet -- -- Dimensions and Interfaces -- -- LED Indicators -- -- Typical System Design and Diagrams Hardware Installation -- -- Internal In Wire-box of The Inverter -- -- Mounting (External in a DAS Box) -- -- Grounding the Unit -- -- Wiring Using the APP...
  • Page 3 Modbus TCP ) Built-in 4G modem ( SIM card included when purchasing the connectivity package, which includes the ENC-G5 gateway card, a SIM card, and access to the YConnect Pro Portal ) Easy mass deployment and configuration via APP using built-in Bluetooth Low Energy (BLE).
  • Page 4: Product Specifications

    Product Specifications Datasheet RS485 Interface No. of Ports 1 ( B: 5-Pole Terminal Block or A: 6-Pin Connector) Protocol Modbus RTU Modbus RTU Mode Master Terminator for RS485 120 ohms Isolation 2.5 kV AUX Interface No. of Ports 1 (3-pole Terminal Block) Protocol Modbus RTU Modbus RTU Mode...
  • Page 5 Modbus TCP Mode Server (Slave) Max. No. of Client Connections Cellular Interface Cellular Standards LTE-FDD/LTE-TDD, WCDMA No. of SIM Slot Cellular Antenna Connectors 1 SMA female Bluetooth Interface Standard BLE 4.2 Antenna Built-in Power Parameters Input Voltage 9 to 24 Vdc Power Consumption 2.5 W, Max.
  • Page 6 Physical Characteristics Housing Plastic IP Rating IP 20 Dimensions 70 mm / 100 mm / 28 mm (2.76 in x 3.94 in x 1.10 in) Weight 73g ( 0.16 lb ) Standards and Certifications (DoC) CE-EMC EN 55032 EN 55035 EN 61000-3-2 EN 61000-3-3 CE-RED...
  • Page 7: Dimensions And Interfaces

    Dimensions and Interfaces Page 6...
  • Page 8 External installation option RS485 Port B Vin GND A+ B- G Caution: Caution: Before configuring the gateway, If the length of the cable connecting to RS485 port or AUX port of pay attention to set the power switch to ON. the gateway is over 1000 meters, the Switch button must be set to ON.
  • Page 9 5 years. Note : ENC gateway is not compatible with third-party sourced SIM card. The Yaskawa Solectria Solar technical support team will not be able to assist in the implementation of third-party SIM cards with this gateway. ENC gateway hardware warranty is valid by default within the validity period of our data plan.
  • Page 10 After the gateway is powered on and working, it will select and connect to the provider network with the strongest or most stable signal. If you are interested in a Yaskawa Solectria Solar Connectivity Package, please contact the YASKAWA Solectria Solar US sales team for detailed information.
  • Page 11: Led Indicators

    Light On Some Devices Found IP ACK Indicates whether the gateway is connected to the YASKAWA Solectria portal target server via the Internet Light Off Unable to connect to LAN router or 4G base station Connected to a LAN router or 4G base station,...
  • Page 12: Typical System Design And Diagrams

    The RS485 interface of the third-party controller is connected to the AUX interface of the gateway, which is equivalent to a direct transmission connection with a daisy chain. Inverter or ESS RS485 Cable YASKAWA Portal RS485 Cable 3rd Party Data Logger...
  • Page 13 System Diagram for Modbus/TCP Pass-through The gateway can be used as a Modbus/TCP server, connect to a third-party SCADA system, and forward various commands to the daisy chain. Inverter or ESS RS485 Cable YASKAWA Portal Ethernet Cable 3rd Party Data Logger / SCADA...
  • Page 14 System Diagram for Connecting Multi-model Devices Using One RS485 The gateway allows users to connect different brands and models of hardware in the same daisy chain via RS485. The connected hardware needs to be pre-compatible with the YASKAWA Solectria Solar YConnect Pro Portal. Inverter or ESS...
  • Page 15: Hardware Installation

    Inverter Router RS485 + YASKAWA Connect Pro APP When the inverters are monitored via the gateway, a unique RS-485 address for each inverter can be set up through the LCD interface. Up to 32 inverters can be connected in the daisy chain network.
  • Page 16 Inverter Wire-Box The Communication Board of Inverter Remove the (3) screws that attach the inverter communication board in the Wire-Box using a #2 Phillips bit. Inverter’s RS485 Port Replace the screws with the (3) standoffs included in the gateway kit. 6-PIN Header Install the gateway by carefully align- ing the 6-PIN connector in the upper...
  • Page 17 Connect the 3rd party Datalogger to the AUX port in the bottom left-hand corner of the gateway using the 3-Pin Connector provided in the gateway kit. RS485 of 3rd Party Data Logger A + / B - / G Optional wire Optional wire RS485 Inverter Daisy Chain A + / B - / G...
  • Page 18 Before closing the cover of POWER ON inverter wire-box, check again that the gateway’s power switch is set to on. Screw one end of the antenna cable into the cable connector of the gateway. Pass the cable through the disassembled cable gland parts in sequence, then tighten the cable glands again.
  • Page 19 Side Mounting (External in a DAS Box) Screw Driver Cover M4 Flat Head Screw DIN-rail Clip As shown in the figure, use a screw- driver to fix the DIN-rail clip and the upper cover of the housing together with M4 flat head screws. Base Put the ENC gateway...
  • Page 20 Align and close the upper and lower housings according to the positions of the screw holes, and fasten the two parts together with M3 screws. Flat Mounting (External in a DAS Box) Put the parts in position in the order of a, b, c, and tighten the corresponding screws. Page 19...
  • Page 21: Grounding The Unit

    Grounding the Unit Clamp the ground wire into the screw at the position shown in the figure, and the gateway is grounded. Wiring Inverter or ESS Meter Weather EV Charger Sensor Model A Model B RS485 Cable Vin GND A+ B- G 5-Pole Terminal Block on gateway A+ B- G...
  • Page 22: Using The App

    Scan the QR-code to complete APP download and installation by using the mobile phones that can access the Internet. Or search for “YASKAWA Connect Pro” in Apple Store and Google Play. Using the APP Check the Internet Connection Installation O&M Service...
  • Page 23 Connect to the adapter Connecting FA1-7012123000203 Connected to FA1-7012123000203 Status ... Processing ... Refresh the list The BLE with the changed name cannot be automatically recogniazed by scanning ! While connecting and configuring the gateway interface, the app will inform users if there are any networking issues to address.
  • Page 24 Ensuring that the Internet Settings Switch FA1-7012123000203 gateway can connect to the Internet is the Select the interface as the channel to the Internet, -> Refresh : 2022-09-16 10:21:32 GMT -6 and configure the corresponding parameters Model : FA1-C most important step. SN : 7012123000203 after switching.
  • Page 25: Modbus Device Settings

    Modbus Device Settings The gateway is config- Daisy Chain Info ured with a default FA1-7012123000203 modbus ID range. Click ID: 1 Scan Enter -> Refresh : 2022-09-16 10:30:32 GMT -6 Model : FA1-C on "Device settings". Model: not scanned SN : 7012123000203 Status: Firmware :...
  • Page 26: Modbus Tcp

    If an exception occurs, first check whether the DHCP two are in the same subnet, or whether the Auto DNS Ethernet cable is properly plugged in. ENC-G5 gateway supports 1 Modbus TCP client. User can change Modbus TCP settings. Page 25...
  • Page 27: Reset / Restart

    Reset / Restart Click "Reset", the gateway will clear all the Settings current setting parameters and restore the factory settings. Baud Rate 9600 N 8 1 Click "Reboot", the gateway will automatically Modbus ID Range power off and restart without changing the current setting parameters.
  • Page 28 Monitoring Support Phone: ( 978 ) 683 9700, Option 5 Hours: 8:30 AM to 5:30 PM (EST) Mon-Fri Email: monitoring@solectria.com Page 27...

Table of Contents