Deployment I/O periphery
Diagnostic and interrupt > Process interrupt

5.9 Diagnostic and interrupt

5.9.1 Overview

Hardware interrupt
Diagnostics interrupt

5.9.2 Process interrupt

128
The parametrization allows you to define the following trigger for a hardware interrupt:
Edge at an digital interrupt input
n
n
Reaching the comparison value
n
Overflow respectively at overrun upper counter limit
n
Underflow respectively at underrun lower counter limit
n
Opening the HW gate with open SW gate - except for counter 3
n
Closing the HW gate with open SW gate - except for counter 3
The VIPA specific parameters allow you to define the following trigger for a diagnostics
Ä Chapter 4.8 'Setting VIPA specific CPU parameters' on page 66:
interrupt
n
Hardware interrupt lost
n
Error: 4L+ DC 24V DO power section supply
n
Error: 3L+: DC 24V DI power section supply
n
Short circuit overload: DO
An interrupt for the corresponding channel operating mode can only be
triggered if you have additionally parameterized 'Diagnostics+Process' at
'Select interrupt' of the 'Basic parameters' .
A process interrupt causes a call of the OB 40. Within the OB 40 you may find the logical
basic address of the module that initialized the process interrupt by using the Local word
6. More detailed information about the initializing event is to find in the local double word
8. The assignment of local double word 8 depends on the parameterized operating mode
of each channel.