Electro-pneumatic Control Panel Display Screens
I/O Status
Status Screen
Screen
I/O
I/O
Status
Screen
60
Icon / / / Field
Field
Active Conditions
Icon
Icon
Field
Active
Active
Digital
Digital Outputs
Digital
Available settings:
(blue) Asserted
(yellow) Not Asserted
SV1
SV1
SV1
Pump fast
SV2
SV2
SV2
Pump slow, pump fast
SV3
SV3
SV3
Ram up
SV4
SV4
SV4
Ram jog, ram down
SV5
SV5
SV5
Seal inflate
SV6
Air assist
SV6
SV6
SV7
SV7
SV7
Seal deflate
Aux
Aux
Aux 1 1 1
Auxiliary 1 output
Aux 2 2 2
Aux
Aux
Auxiliary 2 output
Digital Inputs
Digital
Digital
Aux 1 1 1
Aux
Aux
Auxiliary 1 input
Aux 2 2 2
Aux
Aux
Auxiliary 2 input
Aux
Aux Pulse
Aux
Pulse
Pulse
Total flow meter pulse count
Counter
Counter
Counter
Analog
Analog Outputs
Analog
FR1
FR1
FR1
Pump pressure
FR2
FR2
FR2
Ram pressure
FR3
FR3
FR3
Seal pressure
Analog Inputs
Analog
Analog
Aux 1 1 1 analog
Aux
Aux
analog
analog
Current 4–20 mA scale reading
input
input
input
Ram Position
Position
Ram
Ram
Position
Current ram position reading
Seal Pressure
Pressure
Seal
Seal
Pressure
Current seal pressure reading
Supply Air
Air
Supply
Supply
Air
Current supply air pressure
Pressure
Pressure
Pressure
reading