Run Mode Screens

Status Screen

Use the Up
or Down
Run screens.
Press the Setup
key to enter the Setup screens
from the Status screen.
The other keys have no function in this Status
screen.
1
11
2
7
3
4
5
F
. 12. Status Screen
IG
Key to F
. 12:
IG
1
Active Recipe: shows the active recipe.
NOTE: At power up the system defaults to Recipe
61, which is not a valid recipe number.
2
Target Ratio: for the active recipe. The ratio can be
from 0.0:1–50.0:1, in 0.1 increments.
3
Actual Ratio: in hundredths, calculated after each
dose of A and B.
4
Potlife Timer: shows remaining potlife time in min-
utes. Two times are shown if there are two guns
(manual or semi-automatic mode only).
5
Status Bar: shows current alarm or operation mode
(standby, mix, purge, recipe change, or the current
alarm).
NOTE: If the auto key board is removed from the
EasyKey display board, the Status Bar will read
"Auto key not found." This indicates that the auto-
matic mode is not operable.
24
keys to scroll through the
8
10
9
6
Get other manuals https://www.bkmanuals.com
6
Target Flow Rate and Current Flow Rate: in
cc/min.
7
Animation: when the gun is triggered, the gun
appears to spray and the component A or B hose
lights up, showing which component dose valve is
open.
8
Current Date and Time
9
Screen Number and Scroll Arrows: displays the
current screen number and the total number of
screens in a group. The Up and Down arrows on the
right edge of the screen indicate the scroll feature.
The total number of screens in some groups may
vary depending on system configuration selections.
10
Current Flow Control Data: fluid output pressure
and voltage of analog signal used for driving the
fluid regulator V/P.
11
Lock Symbol: indicates that Setup screens are
password protected. See page 29.
312779E

Advertisement

Table of Contents
loading