12. COMMISSIONING AND CONTROL SETTINGS

All of these heaters have been factory tested, but should be commissioned and adjusted in accordance with the
following instructions to ensure efficient and optimal heating performance.
Remember:
Mains power must be switched OFF before any wiring is touched.
Commissioning must be carried out by a qualified trades person.
If the heater cannot be adjusted to operate in accordance with these instructions, contact the Customer Service
Centre (refer to the back cover).

12.1 SP5 AND SP6 HEATER CONTROL SETTINGS

The heater module has 3 push buttons. On the right is a SET button and on the left are the UP and DOWN buttons.
To change an installer set-up parameter, press and quickly release the SET button, the word "SET" should now
appear on the top line of the screen.
The UP and DOWN buttons may now be used to increase or decrease the value on any setting displayed on the
screen.
By pressing the SET button the display will cycle through the installer set-up parameters in the order on the
following page.