4.5.4 Remote Terminal (Part No. B018384) All Internal Model Applications
In specific installations, for example under the floor, it is recommended that a remote terminal be used to terminate
the flue on the outside wall of the building. Please refer to the instructions supplied with a remote flue terminal.
Diagram 6 depicts a typical SP5 underfloor configuration.
Diagram 6. Typical Remote Terminal Configuration - SP5 Models
BRIVIS REMOTE FLUE TERMINAL
HOUSE FLOOR
FLUE OUTLET
COMBUSTION AIR INLET
GAS
INLET
WALL
Fix in place
Minimum 20 mm rise per 1 metre run
Minimum
300 mm
POWER LEAD
GROUND LEVEL
LEVEL CONCRETE BASE
Single Skin Flue Maximum Length = 2 m
Twin Wall Flue Maximum Length = 6 m
Brivis
16
Ducted Gas Heater IM