Maintenance; Clean Cycle Deliming Procedure - Vulcan-Hart VCE6H ML-126177 Installation And Operation Manual

Electric combi, convection & steam ovens
Table of Contents

Advertisement

WARNING: THE OVEN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING
OR SERVICING THE OVEN. THE COOKING COMPARTMENT CONTAINS LIVE STEAM. STAY
CLEAR WHEN OPENING DOOR.

CLEAN CYCLE DELIMING PROCEDURE

CLEAN CYCLE DELIMING — TANK VOLUME AND CHEMICAL REQUIREMENTS
DO NOT EXCEED THE RECOMMENDED CHEMICAL CONCENTRATION
A.
B.
TANK VOLUME TANK VOLUME
MODEL
U.S.GALLONS
VCE6H
0.8 gal.
VCE10H
1.6 gal.
VCE10F
1.6 gal.
VCE20H
2.6 gal.
VCE20F
3.4 gal.

MAINTENANCE

• With the Programmable Control, select the Clean Cycle [Program Number
00 and
or Program Number 98 and
Program Number, [ dSCL ] will display in the Temperature Display. Push
Start Stop. The indicator light in the Start Stop key will light. For Manual
Controls, turn the Selector Switch to dSCL.
1. The Steam Generator will drain, the oven will beep for 5 seconds, and
[ 40 ] will display in the Time Display and the indicator light in the Start
Stop key will turn off.
2. If the filter system is installed in the water line to the steam generator,
remove the cartridge from the housing, install the dip tube and add the
appropriate amount of ScaleKleen descaling chemicals for the Combi
Model as specified in Column D or E of the following table.
• If there is no filter system installed in the water line to the steam generator,
add the amount of vinegar equal to the Tank Volume as specified in
Column B or C of the following table. Add the vinegar to the steam
generator tank through the opening inside the oven cavity using the
funnel and flexible tube provided with the oven.
C.
QUANTITY OF 7 oz. PACKETS
(QUARTS)
OF SCALEKLEEN TO ACHIEVE
3.2 qts.
6.3 qts.
1.5 packets or 10.5 oz.
6.3 qts.
1.5 packets or 10.5 oz.
10.5 qts.
2.5 packets or 17.5 oz.
13.7 qts.
3.4 packets or 24.0 oz.
3. Press the START button. The door closes and locks and the control
cannot be interrupted until the Clean Cycle is finished. The oven cannot
be turned off. If a power interruption occurs, the Clean Cycle will resume
after power is restored. No other operations can be performed until the
Clean Cycle is 'DONE'.
D.
7 oz / gallon
0.8 packets or 5.6 oz.
– 34 –
. [ CC ] will display as the
E.
QUANTITY OF 2.2 lb. PACKETS
OF SCALEKLEEN TO ACHIEVE
2.2 lb / five gallons
0.16 packets or 5.6 oz.
0.3 packets or 10.5 oz.
0.3 packets or 10.5 oz.
0.5 packets or 17.5 oz.
0.7 packets or 24.0 oz.