Connections
5.2

Encoder interface (X2 on SLE, X21 on SLE-DP)

CAUTION
5-2
02.2001
The encoder interface of the SIMOLINK Encoder is the 9-pin, SUB D
socket with screw locking mechanism (UNC) on the front of the
housing. Three RS422 drivers each supply two signals per pulse
output, one with non-inverted signal level and one with inverted signal
level. The output signals of the encoder interface are isolated from the
24 V supply voltage (X1) and (on the SLE-DP) from the PROFIBUS
interface (X22).
Frequency/signal
generator
Fig. 5-2
Schematic of output circuit
The encoder interface on the SLE module is labeled X2. The encoder
interface on the SLE-DP module has the designation X21, but is also
labeled with "PULSE OUT" and the following symbol:
The connector hardware for both the encoder interface and the
PROFIBUS interface is a 9-pin SUB D socket. The two interfaces are
distinguishable only by their labeling and position (cf. Fig. 4-3). The
plug and socket must be connected correctly by the end-user during
installation.
SLE / SLE-DP – SIMOLINK Encoder
Electrically isolated from
24 V supply voltage
GWE-477 763 4070.76 J
Operating Instructions
1
A+
6
A−
3
B+
8
B−
2
Zero +
7
Zero −
9
GND