Data format of actual-value telegram

31
Momentary actual value
Bit
Designation
31...17
Momentary
actual value
16
-
15...01
Setpoint reached Assigned to internal counter:
00
SLE status
NOTICE
6-10
02.2001
The 32-bit actual-value telegram contains the momentary 15-bit actual
pulse output value, a status bit plus an internal counter value.
32-bit actual-value telegram
17 16 15
Fig. 6-5
SIMOLINK actual-value telegram
Meaning
Momentary 15-bit actual value:
0...32767 corresponds to an encoder revolution of 0...360° or 8192 output
pulses (4096, 2048 and 1024 can also be set on the SIMOLINK Encoder);
the zero pulse is output on transition from 32767 to 0
Unused: Preset to '0'
Setpoint reached by the SIMOLINK Encoder
Status feedback of SIMOLINK Encoder:
'SLE status' = 0
SIMOLINK Encoder is not outputting pulses (not started)
'SLE status' = 0 and 'SLE control' = 1
Activation error: SIMOLINK Encoder has
not been activated via DIL switch S1.5 or
has not been activated via PROFIBUS in the case of SLE-DP or
is indicating an error or
receive telegram set for the SIMOLINK Encoder does not match the setpoint
telegram
'SLE status' = 1
SIMOLINK Encoder is active and outputting pulses
Table 6-8
Meaning of SIMOLINK actual-value telegram
The actual position value that can be read from the SIMOLINK Encoder
is affected by a SIMOLINK-dependent time delay.
SLE / SLE-DP – SIMOLINK Encoder
0
Setpoint reached
GWE-477 763 4070.76 J
Operating Instructions
01 00
Siemens AG
SIMOVERT MASTERDRIVES
S

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Simovert masterdrive sle-dp

Table of Contents