Connections; Connector X1 - Siemens SIMOVERT MASTERDRIVE SLE Operating Instructions Manual

Simolink-encoder
Table of Contents

Advertisement

Available languages

Available languages

SLE / SLE-DP – SIMOLINK Encoder
5

Connections

5.1

Connector X1

Siemens AG
GWE-477 763 4070.76 J
SIMOVERT MASTERDRIVES
02.2001
The SIMOLINK Encoder has
♦ the X1 sockets for voltage supply,
♦ an encoder interface for signal outputs (X2 on SLE, X21 on SLE-
DP) and
♦ a SIMOLINK fiber-optic cable connection with one transmit socket
and one receive socket.
The SLE-DP module also has socket X22 for the PROFIBUS-DP
connection in compliance with EN 50170.
The 6-pin connector is on top of the housing. The 24 V power supply to
the SIMOLINK Encoder is connected via X1 (connector type MINI-
COMBICON MC1.5/6-STF-3.81).
M
+24 V
Socket X1
Fig. 5-1
Terminal
Designation
1
2
3
4
5
M
6
+24 V
Connectable cross-section: 1.5 mm
Terminal 1 is the terminal to the rear of the module top plate (see plan view).
Table 5-1
Connector assignments
Operating Instructions
Connector
Meaning
Ground
24 V voltage supply
2
(AWG 16)
Connections
Range
n.c.
n.c.
n.c.
n.c.
+21 ... 28 V
5-1

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Simovert masterdrive sle-dp

Table of Contents