Perkins 1106D Troubleshooting Manual page 14

Electric power generation
Table of Contents

Advertisement

14
Troubleshooting Section
Operation of the Indicator Lamps
Table 4
Warning
Shutdown
Lamp
Lamp
(Alert
(Action
Lamp)
Lamp)
On
On
Off
Off
On
Off
On
Off
On
On
Off
Off
This document is printed from SPI². Not for RESALE
Diagnostic
Derate
Lamp State
Lamp
Lamp
Lamp Check
On
On
No Faults
Off
Off
Warning
(Warning
only)
Flashing
Off
Derate
(Warning
and Derate)
Flashing
On
Engine
shutdown
(Warning
and
shutdown)
Flashing
Off
Diagnostic
(Diagnostic
only)
Flashing
Off
Description of the Indication
When the keyswitch is switched on,
the lamps come on for a period of
2 seconds and the lamps will then
go off.
With the engine in operation, there
are no active warnings, diagnostic
codes or event codes.
If the warning lamp comes on
during engine operation, and the
diagnostic lamp is flashing , the
lamps indicate that one or more of
the warning values for the engine
protection strategy have been
exceeded and that there is an
active event code. However, the
value has not been exceeded to a
level that will cause a derate or a
shutdown.
If both the warning lamp and the
derate lamp come on during engine
operation, and the diagnostic lamp
is flashing, the lamps indicate that
one or more of the values for the
engine protection strategy have
been exceeded beyond the level
that will cause an engine derate.
If both the warning lamp and
the shutdown lamp come on
during engine operation, and the
diagnostic lamp is flashing, the
lamps indicate that one or more
of the shutdown values for the
engine protection strategy has
been exceeded and there is an
active event code.
When the diagnostic lamp flashes
during operation of the engine,
the lamp indicates that an active
diagnostic code (an electrical fault)
is present. However, the diagnostic
code is not serious enough to
cause a derate or a shutdown.
KENR6201-01
Engine State
The keyswitch is
on but the engine
has not yet been
cranked.
The engine is
operating with no
detected faults.
The engine
is operating
normally.
However, there is
one or more of the
monitored engine
parameters that
are outside of
the range that is
acceptable.
The engine
is operating.
However, one
or more of the
monitored engine
parameters is
outside of the
acceptable range.
The acceptable
range has been
exceeded to
a level which
requires a warning
and an engine
derate.
The engine is
either shutdown
or an engine
shutdown is
imminent.
One or more
monitored engine
parameters have
exceeded the
limit for an engine
shutdown.
The engine is
operating but
there is one or
more faults with
the electronic
system for the
engine.
(continued)