OVERVIEW (CONTINUED)

TERMINAL DESCRIPTION

GND IN OUT
TERMINAL NAME
GND
ALARM IN
ALARM OUT
LINK IN
LINK OUT
TRIGGER OUT
TAPE END
1 SHOT REC
IN OUT TRIG
ALARM
VIH
VIL
T
VIH
VIL
T
VIH
VIL
T
VIH
VIL
T
VIH
VIL
T
VIH
VIL
T
VIH
VIL
T
TAPE
OUT
END
LINK
SIGNAL LEVEL
VIH : 4 ~ 5V
VIL : 0 ~ 0.6V
T
: More than 0.5 second
VIH : 4 ~ 5V
VIL : 0 ~ 0.6V
T
: Alarm Recording
VIH : 4 ~ 5V
VIL : 0 ~ 0.6V
T
: More than 0.5 second
VIH : 4 ~ 5V
VIL : 0 ~ 0.6V
T
: More than 1 second
VIH : 4 ~ 5V
VIL : 0 ~ 0.6V
T
: About 0.02 second
VIH : 4 ~ 5V
VIL : 0 ~ 0.6V
T
: More than 0.25 second
VIH : 4 ~ 5V
VIL : 0 ~ 0.6V
T
: More than 0.5 second
5
1SHOT
REC
GND
INPUT
OUTPUT
INPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
TYPE