Alarm Record - Lorex TR 1285 Installation And Operation Manual

30 hour real time/time lapse vcr, 168/960 hour time lapse vcr
Table of Contents

Advertisement

RECORDING (CONTINUED)

ALARM RECORD

Apply alarm signals to the signal input terminal at the rear panel to enable alarm recording.
ALARM SET INPUT
6H-960H
RECORDING
NORMAL mode
*
Set the alarm recording mode and alarm recording period in the ALARM SETUP screen.
*
An index signal is automatically recorded when alarm recording begins.
If Buzzer is set to ON in the ALARM SETUP screen, the buzzer sounds during the alarm record period.
*
If another alarm signal is received by the SET terminal while the VCR is recording in the alarm mode, it will not trigger a new
alarm recording.
NOTE:
*
The buzzer can be turned off by pressing the CLEAR BUZZER OFF button once.
*
The alarm record mode can be turned off by holding the CLEAR BUZZER OFF button for 3 seconds.
+
AUDIO RECORD CONNECTION
RS232C
RESET
6H-30H
6H-960H
ALARM
RECORDING
RECORDING
ALARM mode
NORMAL mode
GROUND
ALARM SIGNAL
AUDIO
IN
GND IN OUT
IN OUT TRIG
TAPE
1SHOT
OUT
END
REC
OUT
ALARM
LINK
MIC IN
* 6H, 18H and 30H record modes are available
for alarm record.
* Remote alarms can be configured to
VIDEO
sound a buzzer at the VCR by connecting
IN
external alarm signals to the ALARM IN and GND
terminals.
OUT
15

Advertisement

Table of Contents
loading