SINAMICS S120 Fail-Safe Drives
Description
If required, define the
interconnections for the safety
functions in the Drive group windows.
All of the functions are "statically
active (0)" in the default state.
In this example the SS1 function is
interconnected with F-DI0 and SLS
with F-DI1 in Drive group_1 (this
involves Drive_1).
Set safety functions STO, SS2 and
SOS to the state "Statically inactive
(255)".
In this example, the SS1 function is
interconnected with F-DI0 and SLS
with F-DI2 in Drive group_2 (this
involves Drive_2).
Set safety functions STO, SS2 and
SOS to the state "Statically inactive
(255)".