THE CERTIFICATE:
The BEND TEST CERTIFICATE is located in the
STUDENT REPORT, which can be saved and accessed
if there is a USB memory device in the USB slot on the
®
front of the VRTEX
360 while performing the virtual
bend test procedure.
Sample A Root Bend and B Face Bend Guided
Results
Bend Test Certificate
English
SCORING MODULES:
Overview:
After welding a pass, the user can now see whether
each defect/discontinuity was within acceptable
standards (passed) or not (failed). The acceptable
standards implemented in VRTEX
scoring modules. Instructors can use the Instructor Mode
to enable the scoring module they would like to use (i.e.,
AWS D1.1 or ASME). The pass/fail marks will appear on
the LASER screen for relevant passes (scoring modules
do not cover all of the available VRTEX
The SCORING MODULE feature can be used when the
user wishes to have their welding evaluated against the
ASME or AWS D1.1 standards. This option can be
selected by entering the INSTRUCTORS MODE using
the instructor's key. From the Sign In screen, turn the
Instructor's Key 90º to the right. Use the joystick to
highlight SCORING MODULE located at the bottom right
corner of the Instructors Mode screen. Use the red
SELECT button to open the options in the module. Use
the joystick to toggle between Based on ASME
Standards, Based on D1.1 Standards, and None. Use
the red SELECT button to choose a standard. Press the
orange BACK button twice to return to the Sign In
screen.
Instructor Mode (Scoring Modules)
Scoring Modules Select Button