System Monitor; Dc; Ps - Yamaha RX-V381 Service Manual

Hide thumbs Also See for RX-V381:
Table of Contents

Advertisement

RX-V381/HTR-3069
R1. INVALID ITEM
Not for service.
P1. SYSTEM MONITOR
This menu is used to display the A/D conversion
value of the microprocessor which detects panel keys
and protection functions by using the sub-menu.
When "P1-8. KEY1/KEY2" sub-menu is selected, keys
become inoperable due to detection of the values
of all keys. However, it is possible to advance to the
next menu by turning the VOLUME knob.
* Numeric values in the figure are given as reference
only.
P1-1. DC
Power amplifier DC (DC voltage) output is
detected.
The voltage at 100 pin (DC_PRT) of IC221 is
displayed.
Normal value: 27 to 88
* If DC becomes out of the normal value
range, the protection function works to turn
off the power.
P1-2. PS
Power supply voltage (PS) protection detection.
The voltage at 97 pin (PS_PRT) of IC221 are
displayed.
Voltage detects: ACL, AC12, ±12A, ±7A,
Normal value:
* If PS becomes out of the normal value
range, the protection function works to turn
off the power.
50
R1-1
Invalidity
(Reference voltage: 3.3 V=255)
P1-1

DC: 057

+7D, +5A, +3.3D, +40F
112 to 163
(Reference voltage: 3.3 V=255)
P1-2

PS:136/---/---

R1. INVALID ITEM
サービスでは使用しません。
R1-2
Invalidity
P1. SYSTEM MONITOR
パネルキー、プロテクションなどを検出しているマ
イコンの A/D 変換値を、サブメニューで表示します。
サブメニュー "P1-8. KEY1/KEY2" にすると、全キー
の値を検出するためキー操作はできなくなりますが、
VOLUME ツマミを回すことにより、次のメニューに
進めることができます。
※ 図中の数値は参考例です。
P1-1. DC
パワーアンプ DC(直流電圧)出力の検出
IC221 の 100 ピン(DC_PRT)の電圧が表示さ
れます。
正常値:
27 〜 88
(基準電圧:3.3 V=255)
※ DC が正常値を外れるとプロテクションが働
き、電源が切れます。
P1-2. PS
電源電圧(PS)プロテクションの検出
IC221 の 97 ピン(PS_PRT)の電圧が表示され
ます。
検出電圧:
ACL、AC12、±12A、±7A,
+7D、+5A、+3.3D、+40F
正常値:
112 〜 163
(基準電圧:3.3 V=255)
※ PS が正常値を外れるとプロテクションが働
き、電源が切れます。

Advertisement

Table of Contents
loading

This manual is also suitable for:

Htr-3069

Table of Contents