2-2.
When the protection function worked due to
abnormal DC output.
DC PRT:xxxH
Cause: DC output of the power amplifier is abnormal.
Supplementary information: The protection function
worked due to a DC voltage appearing at the speaker
terminal. A cause could be a defect in the amplifier.
Turning on the power without correcting the abnormality
will cause the protection function to work in 5 seconds
and the power supply will be shut off.
2-3.
When the protection function worked due
to abnormal voltage in the power supply
section.
PS PRT:xxxL
Cause: The voltage in the power supply section is
abnormal.
Supplementary information: The protection function
worked due to a defect or overload in the power supply.
Turning on the power without correcting the abnormality
will cause the protection function to work in 1 second and
the power supply will be shut off.
Notes:
• Applying the power to this unit without correcting
the abnormality can be dangerous and cause
additional circuit damage. To avoid this, if "PS"
and "DC" protection function works 3 times
consecutively, the power will not turn on even
when the "z" (Power) key is pressed. In order
to turn on the power again, start up the self-
diagnostic function.
• The output transistors in each amplifier channel
should be checked for damage before applying
power to this unit.
• A m p l i fi e r c u rre n t s h o u l d b e m o n i to re d by
measuring DC voltage across the emitter resistors
for each channel.
H: Displayed when the voltage is HIGHER than upper limit
電圧が上限値より高い場合に表示されます
L: Displayed when the voltage is LOWER than lower limit
電圧が下限値より低い場合に表示されます
xxx: A/D conversion value of voltage at the moment when the protection function worked
(Reference voltage: 3.3 V=255)
プロテクションが働いた瞬間の電圧の A/D 変換値
(基準電圧:3.3 V=255)
原因: パワーアンプの DC 出力が異常。
補足: アンプの故障でスピーカー端子に直流電圧が掛か
異常状態のまま電源を入れると、5 秒後にプロテクション
が働き、電源が切れます。
H: Displayed when the voltage is HIGHER than upper limit
電圧が上限値より高い場合に表示されます
L: Displayed when the voltage is LOWER than lower limit
電圧が下限値より低い場合に表示されます
xxx: A/D conversion value of voltage at the moment when the protection function worked
(Reference voltage: 3.3 V=255)
プロテクションが働いた瞬間の電圧の A/D 変換値
(基準電圧:3.3 V=255)
原因: 電源部の電圧が異常。
補足: 電源電圧による原因で、プロテクションが働いた
異常状態のまま電源を入れると、1 秒後にプロテクション
が働き、電源が切れます。
注意:
• 異常状態のまま本機の電源を入れると、危険な状態
• 本機の電源をいれる前に、各パワーアンプの出力ト
• パワーアンプの電流は、各チャンネルのエミッター
DC 出力異常によりプロテクションが働いた場合
2-2.
るなどが原因で、プロテクションが働いたことを
示します。
電源部の電圧異常によりプロテクションが働い
2-3.
た場合
ことを示します。
になり、さらに回路が損傷を受ける原因になります。
それを避けるために、 「DC」 、 「PS」プロテクション
が連続して 3 回目働いた場合、それ以降 "z"(電源)
キーを押しても電源が入らなくなります。再度電源
を入れる場合、ダイアグを起動してください。
ランジスタに損傷がないかチェックしてください。
の抵抗器間 DC 電圧を測定することによりモニターし
てください。
RX-V381/HTR-3069
33